Speaker System Measurement - Denon AVR-4806CI Operating Instructions Manual

Av surround receiver
Hide thumbs Also See for AVR-4806CI:
Table of Contents

Advertisement

NOTE:
• If the results are not as expected or if an error message is
displayed, select "Retry" and perform the measurements
again. (For details on the error messages (
If the results of remeasurement are still not as expected
or if an error message is displayed, turn off the power
switch and check the speaker connections. Then start the
measurements again from the beginning.
• Measurement is cancelled when MASTER VOLUME is
operated while the Auto Setup is performed.

Speaker system measurement

• With these measurements, the "Speaker Configuration",
"Delay Time", "Channel Level", "Crossover Frequency" and
"Room EQ" are analyzed automatically. The main listening
position is measured first, so leave the microphone where it
is.
1
CURSOR
Press the
Start", then press the
• Measurements for the first point start.
The screen shown at the below appears once the
measurements for the main listening position are
completed.
2
Next the measurements for the second point
will be taken.
Place the microphone at the second listening position.
For instructions on the position in which the
microphone should be placed (
page 25).)
D D or H H button to select "OK
CURSOR
F F button.
page 19).
3
CURSOR
Press the
• Measurements for the second point start.
4
Perform step 2, 3 repeatedly.
The more measurement points, the better the
resulting room correction effect. We recommend a
minimum of 6 measurement points – 8 measurement
points provides the best room correction effect.
5
After measuring at the number of points
according to your listening environment, press
CURSOR
the
"Calculate", then press the
• The speaker system is analyzed.
The amount of time required for the analysis depends
on the number of speakers and the number of
measuring points. The greater the number of speakers
and measuring points, the longer the time required. For
example, for ten speaker systems and 6 measuring
points, the calculations require approximately 6
minutes.
Measurements can be ended when there are 5 or less
measurement locations; however, to obtain better
results, measurements at 6 or more locations is
recommended.
Once the calculations are completed, a screen for
confirming the results of the measurements appears.
23
Easy Setup and Operation
F F button.
D D
or H H button to select
CURSOR
F F button.

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents

Save PDF