Chapter Nine: System Options; Swinger Setting; Code Lockout; Arm/Disarm Options - Marmitek PROGUARD 800 Installation Manual

Hide thumbs Also See for PROGUARD 800:
Table of Contents

Advertisement

As the name suggests, System Options are settings that affect the entire system. This
chapter offers explanations and programming instructions for each of these options.

9.1: Swinger Setting

A sensor defined as Swinger enabled can generate only a limited number of alarms during
a specific time period or during an arming period. The following options are available:
x
One alarm per arming period
x
One alarm per hour
x
One alarm per day
x
One alarm per week
x
No swinger
To program the Swinger setting:
1.
From the Programming menu, select System Options, Swinger [9401].
2.
Select a Swinger setting from the above list.

9.2: Code Lockout

The Code Lockout option locks the keypad for 30 minutes if five unsuccessful attempts
are made to enter the user code.
To program the Code Lockout setting:
1.
From the Programming menu, select System Options, Code Lockout
[9402].
2.
Select Enabled or Disabled.
1
During the 30-minute lockout period, you can still arm and disarm the system using
keyfobs and smartkeys. If one key arming is enabled, you may still arm the system using
the wireless keypad.

9.3: Arm/Disarm Options

The options offered in this section relate to arming and disarming the system.
9.3.1: Forced Arm
Forced arming enables you to arm the system when the system is not ready. This option
allows you to enable or disable Forced arming for the entire system. Additionally, you can
enable or disable Forced arming for each individual zone. For further information, see
section 7.6.5: Force Arm.
To program the Forced Arm setting:
1.
From the Programming menu, select System Options, Arm/Disarm,
Forced Arm [94031].
2.
Select Enabled or Disabled.
ProGuard800™

Chapter Nine: System Options

-57-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proguard 800 series