9.7: PGM Output Options

The PGM is a programmable output that is triggered according to specific system status
conditions.
9.7.1: Output Trigger
The Output Trigger option determines the conditions that activate and deactivate the
PGM output.
To program the Output Trigger:
1.
From the Programming menu, select System Options, PGM Options,
Output Trigger [94071].
2.
Select an Output Trigger option from the following table.
Trigger Option
PGM Not Used
Full Arm
Perimeter Arm
Part Arm
Arm Status
Power Trouble
Tel. Line Trouble
System Trouble
Medical
Burglary
Fire Alarm
Zone Status*
Entry/Exit
Siren
WL Siren
Tone Follower
Table 9.1: PGM Output Trigger Options
* Functions only when the system is disarmed.
1
For certain trigger options, deactivation may be determined by the PGM Cut-off (see
9.12.4: PGM Cut-off). If the PGM Cut-off is programmed as 000 (continuous activation),
the PGM output shall remain activated until it is toggled by the relevant change in system
status.
9.7.2: Output Type
The Output Type option determines whether the PGM output produces a steady or
pulsed output.
To program the Output Type:
1.
From the Programming menu, select System Options, PGM Options,
Output Type [94072].
2.
Select Steady or Pulsed.
1
The Zone Status, Siren and WL Siren trigger options have a fixed Output Type; there is
no need to program an Output Type for these options.
ProGuard800™
Activated by...
The PGM output is disabled
System "Full" armed
System "Perimeter" armed
System "Part" armed
Any arming method
AC Loss or Low Battery conditions
Telephone line supervision trouble
System trouble condition
Medical alarm
Burglary alarm
Fire alarm
Open zones (steady)
Bypassed zones (pulsing)
Entry/Exit delay follower
Built-in siren follower
Wireless siren follower
Keypad Tone Follower
Deactivated by...
System disarmed
or
PGM Cut-off
AC restore or Battery restore
Telephone line restore
System trouble restore
Any arming method,
system disarmed
or PGM Cut-off
All zones closed and no
zones bypassed
-61-