Keyfobs (PR811/KR814)

The PR811 and KR814 are keyfob transmitters that are supported by the system.
REGISTRATION PROCEDURE
To register keyfobs:
1. From the Programming menu, select Devices, Keyfobs [912].
2. Select the keyfob you want to register; the system initiates Registration mode.
3. Press a button, making sure that the keyfob's LED lights up when the button is
pressed.
4. Press the same button again. When Save? appears on the panel's LCD display,
press 9.
PR811
The PR811 is a one-button transmitter that generates a Medical
Emergency alarm when pressed. The transmitter is water resistant
and can be worn around the neck. Its large button makes it ideal
for elderly or sight-impaired users.
When the battery is low, the PR811's LED flashes during
transmission and a Low Battery signal is sent to the receiver. When
either of these two indications are observed, replace the unit.
Figure B.11: KR814
To replace the batteries:
1.
Insert a small screwdriver into the pry-off slot – see
Figure B.12 Carefully twist the screwdriver to
separate the front and back of the casing.
2.
Observing correct polarity, replace the batteries
(3V lithium, size: CR1225).
3.
Close the casing making sure that the front and
back click shut.
ProGuard800™
KR814
The KR814 is a four-button keyfob transmitter that offers a
number of functions including arm, disarm and SOS Panic.
When the battery is low, the KR814's LED flashes during
transmission and a Low Battery signal is sent to the receiver.
When either of these two indications are observed, replace
the batteries.
Figure B.10: PR811
Fi
gure B.12: Opening the
KR814's Casing