Marmitek PROGUARD 800 Installation Manual page 34

Hide thumbs Also See for PROGUARD 800:
Table of Contents

Advertisement

4.7.6: Walk Test
To initiate Walk Test mode:
1.
From the Service menu, select Walk Test [706]; a list of registered
sensors appears.
2.
Trigger each sensor; when the system receives a successful
transmission from a sensor, the sensor is removed from the list.
3.
When all the sensors are removed from the list, End Walk Test is
displayed.
Press 2 to exit Walk Test mode.
4.
4.7.7: Transmitters
The Transmitters menu offers two utilities that serve as a valuable aid during installation.
The first utility, TX List, is a scrollable inventory of all registered transmitters and their last
reported status.
To view the TX list:
1.
From the Service menu, select Transmitters, TX List [7071]; the first
transmitter on the list is displayed.
2.
Using the arrow buttons, scroll through the transmitter list.
When you have finished viewing, press 2to exit the list.
3.
The TX list displays the following information for
each transmitter:
x
The zone/device number or descriptor.
Press the key to toggle the display.
x
The signal strength of the last received
transmission.
x
An
abbreviation
received status of the transmitter – see
Table 4.1.
This...
OK
TA
BT
OS
NA
Table 4.1: Transmitter Status Abbreviations
1
In most cases, an "out of synchronization" condition indicates that an unauthorized
attempt at grabbing the transmission has occurred – i.e. a previous transmission has been
recorded and sent by somebody trying to violate the system.
The second utility, TX Test, enables you to identify transmitters and test their signal
strength.
In TX Test mode, each time a transmission is received, the activated transmitter is
displayed.
-34-
indicating
the
Means...
The transmitter is functioning correctly
Tamper condition
Battery low
The transmitter is out of synchronization
The transmitter is inactive – see section 7.4: Supervision Time
X
ZONE #2
S=6 OK
Y
X
Y
last
Z
Figure 4.3: TX List Display
Z
Descriptor
Signal Strength
Status
© MARMITEK

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: