24Hr-X
The 24Hr-X zone is a future option that is not available in the current firmware.
Gas
Gas zones are always active. In the event of a gas leak, these zones generate a Gas
alarm. Gas zones are typically used with methane/propane/butane or carbon monoxide
gas detectors. Gas alarms sound a distinctive siren pattern to easily distinguish them
from other alarms. A gas alarm causes the siren to sound until the alarm is restored; the
siren cut-off does not apply to gas alarms.
Flood
Flood zones are always active. When triggered, Flood zones generate a Water alarm.
These zones are designed for use with WD861 flood sensors.
Environmental
Environmental zones are always active. When triggered, these zones generate an
Environmental alarm. These zones are designed for applications that monitor
environmental conditions such as temperature or humidity. If the Bell option is enabled
for Environmental zones, the system sounds trouble tones from the keypad. These tones
are sounded until the user presses  on their keypad. Environmental alarms are not
affected by the expiry of the siren cut-off.
No Motion
No Motion zones are used to monitor the activity of disabled or elderly people. If a No
Motion zone has not been triggered within a pre-defined period of time (6, 12, 24, 48 or
72 hours), a No Motion event message is sent to the monitoring station.
Not Used
This zone type disables the sensor output. All alarm transmissions from the sensor are
ignored though the sensor may still be used to activate HA units in Home Automation
applications.
Event Group: Not applicable
Event Group: Fire
Event Group: Burglary
Event Group: Burglary
Event Group: Medical
Event Group: Not applicable