4 | Technical data
4 Technical data
4.1 Operating conditions
4.1.1 Climatic ambient conditions
Storage
Ambient temperature
Relative humidity
Transport
Ambient temperature
Relative humidity
Operation
Ambient temperature
Relative humidity
Degree of protection
Site altitude
4.1.2 Mechanical ambient conditions
Operation
Vibration limits
Shock limit values
4.1.3 Electrical operating conditions
4.1.3.1 Device classification
Requirement
Overvoltage category
Pollution degree
Protection class
24
NORM
-
-
Norm
-
-
Norm
-
-
EN 60529
EN 61010-1
Norm
IEC 60068-2-6
IEC 60068-2-27
Norm
Value
IEC 61010-1
Cat. II
EN 61010-1
2
IEC 61010-2
III
Value
Notes
-40...70 °C
5...85 %
Without condensation
Value
Notes
-40...70 °C
5...85 %
Without condensation
Value
Notes
-20...55 °C
5...85 %
Without condensation
IP20
Only suitable for indoor use
3000 m
From 2000 m above NHN, the ambi-
ent temperature during operation
must be reduced by 0.5°C per 100 m.
Class
Notes
5...9 Hz
7 mm p-p (all 3 axes)
9...150 Hz
1 g (all 3 axes)
±15 g 11 ms
3 pulses per axis and direction
Notes
-
May require installation of the control in a
housing with appropriate degree of protec-
tion, e.g. IPx4
-
ma_ca_c6-compact3-inst-20372037_en