9. Troubleshooting
9.3.6 Detection access
Format: Detection access (field #n, distance mm/azimuth°)
Example:
20
2020/11/18 16:47:25
9.3.7 Detection exit
After at least one detection access event, a detection exit event related to the same field is logged when the
detection signal returns to its default no-motion status.
Depending on the selected verbosity level additional parameters are logged: the detection field number, the
sensor which detected the motion.
Format: Detection exit (field #n)
Example:
20
2020/11/18 16:47:25
9.3.8 Muting status
Every change of the muting status of each sensor is logged as disabled or enabled.
Note: the event indicates a change of the muting status of the system. It does not correspond to the muting
request.
Format: Muting disabled/enabled
Example:
20
2020/11/18 16:47:25
9.3.9 Session authentication
The status of the session authentication and the interface used (USB) are logged.
Format: Session OPEN/CLOSE/WRONG PASSWORD/UNSET PASSWORD/TIMEOUT/CHANGE PASSWORD via USB
Example:
20
2020/11/18 16:47:25
9.3.10 Validation
Every time a validation activity starts or ends on the device, it is logged. The interface used (USB) is logged as
well.
Format: Validation STARTED/ENDED via USB
Example:
20
2020/11/18 16:47:25
9.3.11 Log download
Every time a log download is performed on the device, it is logged. The interface used (USB) is logged as well.
Format: Log download via USB
Example:
20
2020/11/18 16:47:25
72
[INFO]
SENSOR #1
Detection access (field #1, 1200 mm/30°)
[INFO]
CONTROL UNIT
[INFO]
SENSOR#1
Muting enabled
[INFO]
CONTROL UNIT
[INFO]
CONTROL UNIT
[INFO]
CONTROL UNIT
Inxpect Value Line | Instruction manual v1.0 FEB 2025 | Inxpect VL-IM-7_00375_en_v1.0 | © 2025 Inxpect SpA
Detection exit (field #1)
Session OPEN via USB
Validation STARTED via USB
Log download via USB
Need help?