Download Print this page

Other Problems; Event Log Management - Inxpect Value Line Instruction Manual

Advertisement

Status
Application messages
4 flashes *
SENSOR
TEMPERATURE ERROR or
SENSOR POWER ERROR
5 flashes *
MASKING, SIGNAL ERROR Masking, micro-
PERIPHERAL ERROR
6 flashes *
ACCELEROMETER ERROR Inclination of the
Note *: flashes at 200 ms intervals and then with a 2 s pause.

9.1.3 Other problems

Problem
Undesired detections Transit of people or objects in
Machinery in safe
status without
motion in the
detection field
The voltage value
detected on the SNS
input is zero
The system does not
function correctly

9.2 Event log management

9.2.1 Introduction
The event log recorded by the system can be downloaded from the Inxpect Safety application in a PDF file. The
system saves up to 4500 events, divided in two sections. In each section the events are displayed from the most
Inxpect Value Line | Instruction manual v1.0 FEB 2025| Inxpect VL-IM-7_00375_en_v1.0 | © 2025 Inxpect SpA
Wrong power supply
voltage or temperature
value
controller, micro-
controller peripherals,
radar or radar control in
error
Error detected by
diagnostics relative to
the internal micro-
controller, its internal
peripherals or
memories
sensor different from
the installation
inclination
Cause
close proximity to the detection
field
No power supply
Failure of the control unit or one
or more sensors
The chip that detects inputs is
faulty
Control unit error
Sensor error
Problem
Check the sensor connection and that
l
the length of the cables respects
maximum limits.
Check that the ambient temperature
l
where the system is functioning
complies with the operating
temperatures indicated in the technical
data in this manual
Check that the sensor is correctly installed
and that the area is free of any objects
that obstruct the field of view of the
sensors.
If the issue persists, please contact
Technical Support.
Check if the sensor has been tampered
with or if the side screws or fastening
screws are loose.
Change the configuration (see "Change the
configuration" on page 63).
Check electrical connection.
Contact Technical Support if necessary.
Check the status of the LEDs on the control unit (see
"Control unit LED" on page 65).
Access the Inxpect Safety application. On the
Dashboard page, mouse-over
the sensor.
Contact Technical Support.
Check the status of the LEDs on the control unit (see
"Control unit LED" on page 65).
Access the Inxpect Safety application. On the
Dashboard page, mouse-over
the sensor.
Check the status of the LEDs on the sensor (see
"Sensor LED" on the previous page).
Access the Inxpect Safety application. On the
Dashboard page, mouse-over
the sensor.
9.  Troubleshooting