5.4.4 Configure the restart function
Type
Automatic
1. In the Inxpect Safety application in Settings > Restart function, select Automatic.
2. In the Inxpect Safety application, in Configuration for each detection field in use with
Manual
1. In the Inxpect Safety application in Settings > Restart function, select Manual.
2. If there is a digital input configured as Restart signal (Settings > Digital Input-
3. In the Inxpect Safety application, in Configuration for each detection field in use with
Inxpect Value Line | Instruction manual v1.0 FEB 2025| Inxpect VL-IM-7_00375_en_v1.0 | © 2025 Inxpect SpA
automatic restart, set the Restart timeout parameter (or the T
present).
Output), connect the machinery button for the restart signal as convenient (see
"Electrical connections" on page 83).
manual restart, set the Restart timeout parameter (or the T
Procedure
5. Protective functions
parameter, if
OFF
parameter, if present).