2. Safety
Muting: it inhibits the detection capability of one or a group of sensors (see "Muting" on page 30).
l
WARNING! only for Stop signal, Restart signal and Muting. Any fault on the sensors or the control
unit brings the system to the safe state and makes the additional functions unavailable.
Inxpect Value Line is suitable for protecting the human body in the following scenarios:
dangerous area protection
l
indoor and outdoor applications
l
2.1.5 IMPROPER USE
The following is deemed improper use in particular:
any component, technical or electrical modification to the product
l
use of the product outside the areas described in this document
l
use of the product outside the technical details, see "Technical data" on page 79
l
2.1.6 EMC-COMPLIANT ELECTRICAL INSTALLATION
NOTICE: The product is designed for use in an industrial environment. The product may cause interference if
installed in other environments. If installed in other environments, measures should be taken to comply with the
applicable standards and directives for the respective installation site with regard to interference.
2.1.7 GENERAL WARNINGS
Incorrect installation and configuration of the system decreases or inhibits the protective function of the
l
system. Follow the instructions provided in this manual for correct installation, configuration and validation of
the system.
Changes to the system configuration may compromise the protective function of the system. After any
l
changes made to the configuration, validate correct functioning of the system by following the instructions
provided in this manual.
If the system configuration allows access to the dangerous area without detection, implement additional
l
measures (e.g., guards).
The presence of static objects, in particular metallic objects, within the field of view may limit the efficiency of
l
sensor detection. Keep the sensor field of view unobstructed.
Check that the temperature of the areas where the system is stored and installed is compatible with the
l
storage and operating temperatures indicated in the technical data of this manual.
Radiation from this device does not interfere with pacemakers or other medical devices.
l
2.1.8 WARNINGS FOR THE RESTART PREVENTION FUNCTION
The restart prevention function is not guaranteed in blind spots. If required, implement adequate additional
l
measures in those areas.
Machinery restarting must be enabled only in safe conditions. The button for the restart signal, when needed,
l
must be installed:
outside of the dangerous area
o
not accessible from the dangerous area
o
in a point where the dangerous area is fully visible
o
2.1.9 RESPONSIBILITY
The machinery manufacturer and system installer are responsible for the operations listed below:
Providing adequate integration of the output signals of the system.
l
Checking the monitored area of the system and validating it based on the needs of the application.
l
Following the instructions provided in this manual.
l