16. *SAV {n}
Save the test conditions for later recall (up to 15 steps each) in memory location: 1-
50.
17. *RCL (?) {n}
Recall the test conditions that have been saved (up to 15 steps each) in memory
location 1 - 50.
18. CLER
Resets the instrument from interface control. The address function is till in
effect.
19. *IDN
Checks the instrument for identification.
20. *DDT (?) {n | c}
Determines the response from the interface when the instrument receives TRG or GET
command.
21. *TRG
Triggers the instrument and functions the same as interface message GET. This is
dependent on the setting of DDT, see above.
22. *RST
Resets the instrument and functions the same as interface message SDC
Maintenance & Calibration 3-8
www.valuetronics.com
0 or S
Stop testing
1 or T
Start testing
2 or NS
Stops testing after receiving TRG or GET command and
DDT will change to NT.
3 or NT
Starts testing after receiving TRG or GET command and
DDT will change to NS.