Environmental and Protection Specifications
Table 3-4.
Environmental Specifications
Feature
Protection class
Operating temperature 0° to 45° C without derating
Storage temperature
Humidity
Altitude
Vibration
Protection features
3.6
STO Specifications
Functional safety has been verified by the manufacturer.
Table 3-5.
STO/Functional Safety Specifications
Feature
Nominal voltage
Voltage levels
Power supply – external
Power supply – internal
Maximum reaction time
Quick Start Guide
错误!使用"开始"选项卡将 Heading 1 应用于要在此处显示的文字。
Specification
Degree of protection: IP20
Pollution level: IEC 60664-1 class 2
Do not use in environments where exposed to: corrosive or
flammable gases, water, oil or chemicals, dust (including iron
powder), and salt
45° to 55° C with derating
-20° to 70° C
10 to 90% (no condensation)
<1000 m, according to IEC 61800-5-1
5.88 m/s
2
, 10–60Hz
Includes but is not limited: dynamic braking (hardware)
low/overvoltage, overcurrent, drive and motor overheating, motor
overload protection, driver overload protection, feedback loss,
non-configuration, circuit failure.
Specification
24 VDC
15–30 VDC
STO function not active (motion allowed)
0–5 VDC
STO function active (motion not allowed)
5–15 VDC
STO function not defined and not guaranteed
SELV/PELV required
STO jumper required
30 ms