Extreme Networks Summit Summit1i Hardware Installation Manual page 172

Consolidated i series
Hide thumbs Also See for Summit Summit1i:
Table of Contents

Advertisement

Alpine 3800 Series I/O Modules
Table 55: RJ-21 connector and wire pairs (continued)
VDSL
Ring Side
Port
Pin Number/Wire Color
7
7 orange red
8
8 green red
LEDs
The FM-8Vi module has the following LEDs:
• Module status
• Port status
For information about the LEDs and their activity on the FM-8Vi module, see "I/O Module LEDs" on
page 175.
Software Requirements
The FM-8Vi module requires that the SMMi has ExtremeWare version 6.1.5 or later and BootROM 6.5 or
later. For more information about software requirements and module configuration, see the ExtremeWare
Release Notes Software Version 6.1.5w2.01 Rev1. The FM-8Vi module also requires a connection to the
Mogul-100. For more information about Mogul-100 configuration, see the Mogul-100 Quick Guide.
Configuring the FM-8Vi. The VDSL connection from the FM-8Vi to the Mogul-100 is automatically
established by the hardware on the two devices. There are no commands to configure this VDSL
connection.
However, the VDSL ports on the FM-8Vi connect to the Mogul-100 in such a way that the Ethernet port
on the Mogul-100 behaves as though it is located on the Alpine switch. When you configure a port on
the FM-8Vi, you are configuring the Ethernet port on the Mogul-100. For example, when you add port 2
on the FM-8Vi to a VLAN, the Ethernet port on the Mogul-100 connected to port 2 of the FM-8Vi now
belongs to that VLAN.
The ports on the Mogul-100 that are controlled by the FM-8Vi accept configurations using the same
commands and procedures as the ports on the FM-32Ti and FM-24Fi modules, except that the ports can
only be configured for 10 Mbps.
The slot configuration command now includes a keyword to specify the FM-8Vi. To configure the slot
for the FM-8Vi, use the following command:
config slot <slot> module fm8v
The following example configures slot 2 for the FM-8Vi module:
config slot 2 module fm8v
Displaying VDSL Statistics. For the FM-8Vi module, the show port command has been enhanced to
show VDSL statistics. To display VDSL statistics, use the following command:
show port <portlist> vdsl stats
The following command displays the VDSL statistics for ports 2:1 through 2:4:
show port 2:1-2:4 vdsl stats
172
Tip Side
Pin number/Wire Color
32 red orange
33 red green
Extreme Networks Consolidated "i" Series Hardware Installation Guide