5.3.1
Changing position of the system plug
8020200/15ZT/2019-11-14 | SICK
Subject to change without notice
Make sure that no small objects (e.g. cables) are in the protective field, even if the
b
safety outputs do not switch to the OFF state as a result.
Mount the safety laser scanner so that the status indicators are clearly visible.
b
Mount the safety laser scanner so that you can plug in and pull out the system
b
plug.
Take appropriate measures for vibration damping if vibration and shock specifica‐
b
tions exceed the values and test conditions specified in the data sheet,
sheet", page
159.
For machines that vibrate heavily, use thread-locking compounds to prevent the
b
possibility of fixing screws coming loose unintentionally.
Make sure that the safety laser scanner is aligned correctly, even during mount‐
b
ing: if the safety laser scanner is intended to monitor an area of 270° on a corner,
the safety laser scanner may be mounted rotated by a maximum of 2.5° about the
vertical axis.
Location of the scan plane:
b
Take account of the tightening torque for the fixing screws:
b
M5 at rear/at side = 4.5 Nm ... 5.0 Nm
°
M4 at rear/at side = 2.2 Nm ... 2.5 Nm
°
Higher tightening torques may damage the thread. Lower tightening torques do not
offer sufficient protection against slipping of the safety laser scanner due to vibra‐
tions, for example.
Overview
The system plug is installed at the bottom or rear when the safety laser scanner is deliv‐
ered. You can change the position of the system plug if needed.
Prerequisites
Tool required:
•
TX20 Torx wrench
Approach
1.
Loosen the screws of the system plug.
2.
Carefully remove the system plug from the safety laser scanner.
see "Dimensional drawings", page
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
5
MOUNTING
see "Data
185.
71