SICK microScan3 PROFINET Technical Information

SICK microScan3 PROFINET Technical Information

Safety laser scanner, tia portal
Hide thumbs Also See for microScan3 PROFINET:

Advertisement

Quick Links

T E C H N I C A L I N F O R M A T I O N
microScan3 - PROFINET
Safety laser scanner
TIA Portal

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the microScan3 PROFINET and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK microScan3 PROFINET

  • Page 1 T E C H N I C A L I N F O R M A T I O N microScan3 - PROFINET Safety laser scanner TIA Portal...
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
  • Page 3: Table Of Contents

    Notes on implementing the process images........ 16 Troubleshooting................. 18 8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET Subject to change without notice...
  • Page 4: About This Document

    Depending on the application, it is possible that this example may not suit your specific application case. The experts at SICK can, on request, assist you with the integration. SICK cannot guarantee that the following integration example will be error-free when implemented, e.g., due to future changes to SIMATIC Manager STEP 7.
  • Page 5 ✓ The check mark denotes the result of an instruction. 8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET Subject to change without notice...
  • Page 6: Integration

    Always install the latest GSDML file in the controller. Approach The current GSDML file for integrating the safety laser scanner into the controller can be downloaded at www.sick.com. In TIA Portal: Options > Manage general station description files Select the folder containing the GSDML file.
  • Page 7: Integrating The Safety Laser Scanner

    In the Network view tab: Double-click on microScan3. Alternatively, use drag and drop to drag microscan3 into the working range. You will find microScan3 under Other field devices > PROFINET IO > Sensors > SICK AG. Right-click on Not assigned and select Assign to new IO controller.
  • Page 8 If applicable, right-click on the standard module (highlighted in yellow) and select Delete to remove it. T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET 8026545/2021-03-15 | SICK Subject to change without notice...
  • Page 9 13. If applicable, enter the f_WD_Time. see "Overview of the PROFIsafe parameters", page 11 8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET...
  • Page 10 The safety laser scanner has been successfully integrated into the hardware con‐ figuration. T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET 8026545/2021-03-15 | SICK Subject to change without notice...
  • Page 11: Overview Of The Profisafe Parameters

    8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET...
  • Page 12: Overview Of The Process Images

    • Only a limited range of peripheral addresses are available in your application. • The microScan3 PROFINET is replacing a safety laser scanner of type S3000 PROFINET. • The safety software for your S7 does not support 12-byte process images.
  • Page 13 Cut-off paths 5 to 8 are only available for the Pro performance package. 8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET...
  • Page 14 Cut-off paths 5 to 8 are only available for the Pro performance package. T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET 8026545/2021-03-15 | SICK Subject to change without notice...
  • Page 15 If Start address is set to the value 17, then the output bit 0.0 in the logic can be accessed as Q17.0. The input bit 3.1 then corresponds to I20.1. 8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET...
  • Page 16: Notes On Implementing The Process Images

    All fields are clear in this example (no field detection). T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET 8026545/2021-03-15 | SICK Subject to change without notice...
  • Page 17 NOTES ON IMPLEMENTING THE PROCESS IMAGES 8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET Subject to change without notice...
  • Page 18: Troubleshooting

    (6 bytes or 12 bytes) selected T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET 8026545/2021-03-15 | SICK Subject to change without notice...
  • Page 19 6 bytes. 8026545/2021-03-15 | SICK T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET...