9. Technical data
9.1. Environmental
Operational ambient temperature range: ‐10 ... 50°C, Frost and condensation free
Storage ambient temperature range: ‐40 ... 60°C
Maximum altitude: 2000m. Derate above 1000m : 1% / 100m
Maximum humidity: 95%, non‐condensing
9.2. Rating tables
200‐240V ±10% ‐ 1 Phase Input
3 Phase Output with Internal RFI Filter
Model
kW
(kW)
ODP‐12037
0.37
ODP‐12005‐USA
ODP‐12075
0.75
ODP‐12010‐USA
ODP‐12150
1.5
ODP‐12020‐USA
ODP‐22150
1.5
ODP‐22020‐USA
ODP‐22220
2.2
ODP‐22030‐USA
NOTE
For cUL compliance, fuse type Bussmann KTN‐R / KTS‐R or equivalent must be used
200‐240V ±10% ‐ 3 Phase Input drive model set for 1 Phase Operation (See section 5.10)
3 Phase Output with Internal RFI Filter
Model
kW
ODP‐32030
1.5
ODP‐32040‐USA
ODP‐32040
2.2
ODP‐32050‐USA
ODP‐32055
3
ODP‐32075‐USA
ODP‐42075
4
ODP‐42100‐USA
ODP‐42110
5.5
ODP‐42150‐USA
ODP‐42150
7.5
ODP‐42200‐USA
ODP‐42185
9
ODP‐42250‐USA
ODP‐52220
11
ODP‐52300‐USA
ODP‐52300
15
ODP‐52400‐USA
ODP‐52370
18.5
ODP‐52500‐USA
ODP‐52450
22
ODP‐52600‐USA
ODP‐62055
30
ODP‐62075‐USA
ODP‐62075
37
ODP‐62100‐USA
ODP‐62090
45
ODP‐62120‐USA
Values shown in brackets are the maximum for UL applications
NOTE
For cUL compliance, fuse type Bussmann KTN‐R / KTS‐R or equivalent must be used
GV
Optidrive Plus 3
User Guide
www.invertek.co.uk
Model
HP
Frame
(HP)
Size
0.5
1
1
1
2
1
2
2
3
2
Model
HP
Frame
Size
2
3
3
3
4
3
5
4
7.5
4
10
4
12
4
15
5
20
5
25
5
30
5
40
6
50
6
60
6
Nominal
Fuse or
Supply
Input
MCB
Cable
Current
(type B)
Size
2
Amps
Amps
mm
6.7
6
1
12.5
10
1.5
19.3
20
4
19.3
20
4
28.8
32
6
Nominal
Fuse or
Supply
Input
MCB
Cable Size
Current
(type B)
2
Amps
Amps
mm
19.3
20
4
28.8
32
6
31.3
40
6
58.3
63
10
67.6
80
16
87.0
100
25
96.1
100
25
115.4
125
35
146.1
160
50
187.8
200
70
220.6
250
90
271.5
315
120
319.6
400
120
378.0
400
170
Nominal
150%
Motor
Output
Output
Current
Current
60 secs
Amps
Amps
2.3
3.45
4.3
6.45
7
10.5
7
10.5
10.5
15.75
Nominal
150% Output
Output
Current 60
Cable Size
Current
secs
Amps
Amps
7
11.5
9
13.5
12.5 (12)
18.75 (18)
19.5
29.25
23
34.5
30.5
45.25
36
54
45
67.5
55
82.5
75
112.5
90
135
101
151.5
120
180
150
225
Max
Min
Cable
Motor
Brake
Size
Cable
Res
Length
Value
2
mm
m
Ω
1
25
‐
1
25
‐
1.5
25
‐
1.5
100
33
1.5
100
22
Motor
Max Motor
Min
Cable
Brake
Length
Res
Value
2
mm
m
Ω
1.5
100
15
1.5
100
15
2.5
100
15
2.5
100
6
4
100
6
10
100
6
10
100
6
16
100
3
16
100
3
25
100
3
25
100
3
35
100
3
55
100
3
70
100
3
27
Need help?