U: Monitors - Omron J1000 User Manual

J1000 series compact general purpose inverter
Hide thumbs Also See for J1000:
Table of Contents

Advertisement

No.
Name
Accumulated
Sets the value for the cumulative operation time of the drive in units
o4-01
Operation Time
of 10 h.
Setting
Determines, how the cumulative operation time (U4-01) is counted.
Accumulated
0: Logs power-on time
o4-02
Operation Time
1: Logs operation time when the drive output is active (output
Selection
operation time).
Cooling Fan
o4-03
Operation Time
Sets the value of the fan operation time in units of 10 h.
Setting
Capacitor
o4-05
Maintenance
Sets the value of the capacitor maintenance time monitor U4-05.
Setting
Soft Charge
Bypass Relay
Sets the value of the Soft Charge Bypass Relay Maintenance
o4-07
Maintenance
monitor U4-06.
Setting
IGBT
o4-09
Maintenance
Sets the value of the IGBT Maintenance monitor U4-07.
Setting
Selects if U2- (Fault History) monitors are reset at drive
U2 Initialize
initialization.
o4-11
Selection
0: Saves the fault monitor data
1: Resets the fault monitor data
<12> Default setting value is dependent on parameter o2-04, Drive Model Selection.
<22> Parameter can be changed during run.
u

U: Monitors

Monitor parameters allow the user to view drive status, fault information, and other information about drive operation.
No.
Name
Frequency
U1-01
Monitors the frequency
Reference
U1-02 Output Frequency Displays the output frequency. Display units are determined by
o1-03.
U1-03 Output Current
Displays the output current.
Output Voltage
U1-06
Displays the output voltage.
Reference
U1-07 DC Bus Voltage
Displays the DC bus voltage.
Displays the input terminal status.
U1-10 Input Terminal
Status
Displays the output terminal status.
Output Terminal
U1-11
Status
U1-13 Terminal Input
Displays analog input A1 level: 100% when input is 10 V or 20
Level
mA.
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Description
o4: Maintenance Period
Use o4 parameters to perform maintenance.
Description
U1: Operation Status Monitors
Use U1 monitors to display the operation status of the drive.
Digital input terminal
S1 enabled
Digital input terminal
S2 enabled
Digital input terminal
S3 enabled
Digital input terminal
S4 enabled
Digital input terminal
S5 enabled
Multi-Function
Digital Output (fault)
(terminal MA/MB-MC)
B.2 Parameter Table
Range
Def.
Mode
0 to 9999
0
O
0, 1
0
O
0 to 9999
0
O
0 to 150
0%
O
0 to 150
0%
O
0 to 150
0%
O
0, 1
0
O
Analog Output
Unit
Level
10 V: Max frequency 0.01 Hz
10 V: Max frequency 0.01 Hz
10 V: Drive rated
0.01A
current
10 V: 200 Vrms (400
0.1 V
Vrms)
10 V: 400 V (800 V)
1 V
No output signal
available
No output signal
available
10 V/20 mA: 100%
0.1%
Addr.
Pg.
Hex
50B
114
50C
114
50E
114
51D
114
523
114
525
114
510
115
Addr.
Mode
Hex
O
40
O
41
O
42
O
45
O
46
O
49
O
4A
O
4E
B
181