Single/Three-Phase 200 V Class Drive; Single/Three-Phase 200 V Class Drive - Omron J1000 User Manual

J1000 series compact general purpose inverter
Hide thumbs Also See for J1000:
Table of Contents

Advertisement

A.2 Single/Three-Phase 200 V Class Drive
Three-Phase: JZA
Single-Phase: JZA
Maximum Motor Size Allowed (kW)
Input Current (A)
Input
<3>
Rated Output Capacity (kVA)
Output Current (A)
Output
Max Output Voltage (V)
Max Output Frequency (Hz)
Power
Supply
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Harmonic Corrective Actions
<1> Drives with a single-phase power supply input output three-phase power, and cannot run a single-phase motor.
<2> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater
than the motor rated current.
<3> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to Swing PWM. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency is set to 10 kHz. Current derating is required in order to raise the carrier frequency.
<7> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
Note: Differences between Heavy Duty (HD) ratings and Normal Duty (ND) ratings for the drive include rated input and output current, overload
capacity, carrier frequency and current limit. Set parameter C6-01 to "0" (default) for HD or "1" for ND.
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Table A.2 Power Ratings
Item
<1>
HD Rating
<2>
ND Rating
HD Rating
Three-Phase
ND Rating
HD Rating
Single-Phase
ND Rating
HD Rating
<4>
ND Rating
HD Rating
ND Rating
Overload Tolerance
Carrier Frequency
Rated Voltage
Rated Frequency
DC Reactor
A.2 Single/Three-Phase 200 V Class Drive
20P1
20P2
20P4
B0P1
B0P2
B0P4
0.1
0.2
0.4
0.2
0.4
0.75
0.7
1.5
2.9
1.1
1.9
3.9
1.4
2.8
5.5
2.0
3.6
7.3
0.3
0.6
1.1
0.5
0.7
1.3
<6>
<6>
0.8
1.6
3.0
<5>
1.2
1.9
3.5(3.3)
ND Rating: 120% of rated output current for 1 minute
HD Rating: 150% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
2 kHz (user-set, 2 to 15 kHz)
Three-phase 200 to 240 V (proportional to input voltage)
400 Hz (user-adjustable)
Three-phase power: Three-phase 200 to 240 V 50/60 Hz
Single-phase power: 200 to 240 V 50/60 Hz
Specification
20P7
21P5
22P2
B0P7
B1P5
-
0.75
1.5
2.2
1.1
2.2
3.0
5.8
7.5
11.0
7.3
10.8
13.9
11.0
14.1
-
13.8
20.2
-
1.9
3.0
4.2
2.3
3.7
4.6
<6>
<6>
<7>
5.0
8.0
11.0
6.0
9.6
12.0
-15 to 10%
±5%
Optional
24P0
-
4.0
5.5
18.9
24.0
-
-
6.7
7.5
<7>
<7>
17.5
19.6
A
163

Advertisement

Table of Contents
loading

Table of Contents