Ul Standards; Ul Standards; Ul Standards Compliance - Omron J1000 User Manual

J1000 series compact general purpose inverter
Hide thumbs Also See for J1000:
Table of Contents

Advertisement

D.3 UL Standards
D.3 UL Standards
The UL/cUL mark applies to products in the United States and Canada indicates that UL has performed product testing
and evaluation and determined that their stringent standards for product safety have been met. For a product to receive UL
certification, all components inside that product must also receive UL certification.
u

UL Standards Compliance

This drive is tested in accordance with UL standard UL508C, E131457 and complies with UL requirements. The following
conditions must be met to maintain compliance when using this drive in combination with other equipment:
n
Installation Area
Do not install the drive to an area greater than pollution severity 2 (UL standard).
n
Main Circuit Terminal Wiring
OYMC recommends using UL-listed copper wires (rated at 75 °C) and closed-loop connectors or CSA-certified ring
connectors sized for the selected wire gauge to maintain proper clearances when wiring the drive. Use the correct crimp
tool to install connectors per manufacturer recommendation.
by JST Corporation.
Table D.5 Closed-Loop Crimp Terminal Size (JIS C 2805) (same for 200 V and 400 V)
Wire Gauge
Terminal
2
Screws
mm
(AWG)
0.75 (18)
1.25 (16)
2 (14)
3.5/5.5 (12/10)
Note: Use crimp insulated terminals or insulated shrink tubing for wiring connections. Wires should have a continuous maximum allowable
temperature of 75 °C 600 Vac UL-approved vinyl-sheathed insulation.
Drive Model
JZA
B0P1
B0P2
B0P4
B0P7
B1P5
20P1
20P2
20P4
20P7
21P5
22P2
24P0
40P2
40P4
40P7
41P5
42P2
43P0
218
Figure D.7 UL/cUL Mark
Crimp Terminal
Model Numbers
M3.5
R1.25-3.5
M4
R1.25-4
M3.5
R1.25-3.5
M4
R1.25-4
M3.5
R2-3.5
M4
R2-4
M4
R5.5-4
Table D.6 Recommended Input Fuse Selection
Class T Fuses
Model
Fuse Ampere Rating
200 V Class Single-Phase Drives
A6T15
A6T20
A6T20
A6T40
A6T40
200 V Class Three-Phase Drives
A6T10
A6T10
A6T15
A6T20
A6T25
A6T30
A6T40
400 V Class Three-Phase Drives
A6T10
A6T10
A6T20
A6T25
A6T25
A6T25
U L
C
US
R
LISTED
Table D.5
lists a suitable closed-loop connector manufactured
15
CR6L-20/UL
20
CR6L-30/UL
20
CR6L-50/UL
40
CR6L-75/UL
40
CR6L-100/UL
10
CR6L-20/UL
10
CR6L-20/UL
15
CR6L-20/UL
20
CR6L-30/UL
25
CR6L-50/UL
30
CR6L-50/UL
40
CR6L-75/UL
10
CR6L-20/UL
10
CR6L-20/UL
20
CR6L-50/UL
25
CR6L-50/UL
25
CR6L-50/UL
25
CR6L-50/UL
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Tightening Torque
N m (lb to in.)
0.8 to 1.0 (7.1 to 8.9)
1.2 to 1.5 (10.6 to 13.3)
0.8 to 1.0 (7.1 to 8.9)
1.2 to 1.5 (10.6 to 13.3)
0.8 to 1.0 (7.1 to 8.9)
1.2 to 1.5 (10.6 to 13.3)
1.2 to 1.5 (10.6 to 13.3)
Class L Fuses
Model
Fuse Ampere Rating
20
30
50
75
100
20
20
20
30
50
50
75
20
20
50
50
50
50

Advertisement

Table of Contents
loading

Table of Contents