C.9 Message Examples
Below are some examples of command and response messages.
u

Reading Drive MEMOBUS/Modbus Register Contents

Using the function code 03H (Read), a maximum of 16 MEMOBUS/Modbus registers can be read out at a time.
The following table shows message examples when reading status signals, error details, data link status, and frequency
references from the slave 2 drive.
Command Message
Slave Address
Function Code
Upper
Starting No.
Lower
Upper
Data Quantity
Lower
Upper
CRC-16
Lower
u

Loopback Test

Function code 08H performs a loopback test. This test returns a response message with exactly the same content as the
command message and can be used to check the communications between the master and slave. User-defined test code
and data values can be set.
The following table shows a message example when performing a loopback test with the slave 1 drive.
Command Message
Slave Address
Function Code
Upper
Test Code
Lower
Upper
Data
Lower
Upper
CRC-16
Lower
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Response Message (normal)
02H
Slave Address
03H
Function Code
00H
Data Quantity
20H
1st storage
register
00H
04H
Next storage
register
45H
F0H
Next storage
register
Next storage
register
CRC-16
Response Message (normal)
01H
Slave Address
08H
Function Code
00H
Test Code
00H
A5H
Data
37H
DAH
CRC-16
8DH
02H
Slave Address
03H
Function Code
08H
Error Code
Upper
00H
CRC-16
Lower
65H
Upper
00H
Lower
00H
Upper
00H
Lower
00H
Upper
01H
Lower
F4H
Upper
AFH
Lower
82H
01H
Slave Address
08H
Function Code
Upper
00H
Error Code
Lower
00H
CRC-16
Upper
A5H
Lower
37H
Upper
DAH
Lower
8DH
C.9 Message Examples
Response Message (fault)
02H
83H
03H
Upper
F1H
Lower
31H
Response Message (fault)
01H
89H
01H
Upper
86H
Lower
50H
C
197

Advertisement

Table of Contents
loading

Table of Contents