Selects the carrier frequency
1 : 2.0 kHz
2 : 5.0 kHz
3 : 8.0 kHz
Carrier Frequency
4 : 10.0 kHz
C6-02
Selection
5 : 12.5 kHz
6 : 15.0 kHz
7 : Swing PWM
8 to E : No setting possible
F : User defined (determined by C6-03 through C6-05)
C6-03 Carrier Frequency
C6-03 and C6-04 set upper and lower limits for the carrier
Upper Limit
frequency.
C6-04 Carrier Frequency
Lower Limit
The coefficient K depends on C6-03:
C6-03 ≥ 10.0 kHz: K = 3
10.0 kHz > C6-03 ≥ 5.0 kHz: K = 2
5.0 kHz > C6-03: K = 1
When C6-05 ≤ 6, C6-04 is disabled (makes the carrier frequency
C6-03 value).
C6-05 Carrier Frequency
Sets the relationship of output frequency to carrier frequency when
Proportional Gain
C6-02 = F.
<8> Default setting value is dependent on parameter C6-02, Carrier Frequency Selection.
<22> Parameter can be changed during run.
<57> Default setting value is dependent on parameter o2-04, Drive Model Selection and C6-01, Drive Duty Selection.
u

d: References

Reference parameters are used to set the various frequency reference values during operation.
No.
Name
d1-01
Frequency
Frequency reference
<22>
Reference 1
d1-02
Frequency
Frequency reference when digital input "Multi-Step Speed
<22>
Reference 2
Reference 1" (H1- = 3) is on.
d1-03
Frequency
Frequency reference when digital input "Multi-Step Speed
<22>
Reference 3
Reference 2" (H1- = 4) is on.
d1-04
Frequency
Frequency reference when digital inputs "Multi-Step Speed
<22>
Reference 4
Reference 1, 2" (H1- = 3 and 4) are on.
d1-05
Frequency
Frequency reference when digital input "Multi-Step Speed
<22>
Reference 5
Reference 3" (H1- = 5) is on.
d1-06
Frequency
Frequency reference when digital inputs "Multi-Step Speed
<22>
Reference 6
Reference 1, 3 " (H1- = 3 and 5) are on.
d1-07
Frequency
Frequency reference when digital inputs "Multi-Step Speed
<22>
Reference 7
Reference 2, 3" (H1- = 4 and 5) are on.
d1-08
Frequency
Frequency reference when multi-function input "Multi-Step speed
<22>
Reference 8
reference 1, 2, 3" (H1- = 3, 4, 5) are on.
d1-17
Jog Frequency
Frequency reference when digital inputs "Jog Frequency
<22>
Reference
Reference", "Forward Jog" or "Reverse Jog." are on.
Sets the frequency reference upper limit as a percentage of
Frequency
maximum output frequency (E1-04). Output speed is limited to this
d2-01
Reference Upper
value even if the frequency reference is higher. This limit applies
Limit
to all frequency reference sources.
Sets the frequency reference lower limit as a percentage of
Frequency
maximum output frequency (E1-04). Output speed is limited to this
d2-02
Reference Lower
value even if the frequency reference is lower. This limit applies to
Limit
all frequency reference sources.
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Description
carrier frequency
C6-03
C6-04
output frequency
× (C6-05) × K
E1-04
max output
frequency
Description
d1: Frequency Reference
Use d1 parameters to configure the drive frequency reference.
d2: Frequency Upper and Lower Limits
Use d2 parameters to configure the frequency reference limits.
d3: Jump Frequency
Use d3 parameters to configure the drive Jump Frequency settings.
Range
1 to F
1.0 to 15.0
output
frequency
1.0 to 15.0
00 to 99
Range
0.00 to
400.00 Hz
<19>
0.0 to 110.0 100.0%
0.0 to 110.0 0.0%
B.2 Parameter Table
Addr.
Def.
Mode
Hex
<57>
S
224
<8>
O
225
<8>
O
226
<8>
O
227
Addr.
Def.
Mode
Hex
0.00 Hz
S
280
0.00 Hz
S
281
0.00 Hz
S
282
0.00 Hz
S
283
0.00 Hz
O
284
0.00 Hz
O
285
0.00 Hz
O
286
0.00 Hz
O
287
6.00 Hz
S
292
O
289
O
28A
Pg.
79
80
80
80
Pg.
82
82
82
82
82
82
82
82
82
83
83
B
173

Advertisement

Table of Contents
loading

Table of Contents