Change In Logic Of Near-Point (Dog) Signal (Dszr Instruction; Change In Logic Of Zero-Phase Signal (Dszr Instruction - Mitsubishi MELSEC-F FX3U Series User Manual

Hide thumbs Also See for MELSEC-F FX3U Series:
Table of Contents

Advertisement

FX
/FX
Series PLC User's Manual - Positioning Control Edition
3U
3UC
Built-in Positioning Function
Clear signal device specification method:
1) Write the CLEAR signal output (Y) device number in "Clear signal device specification" device by a
hexadecimal number (expressed octal numbers).
e.g. setting H0010 means Y010. When setting H0008, an operation error occurs because Y008 does not
exist.
2) Turn on "CLEAR signal output enable" flag and "Clear signal device specification function enable" flag of
the pulse output designation device to specify the CLEAR signal device.
3) Execute DSZR instruction (zero return instruction with DOG search function) or ZRN instruction (zero
return instruction).
Example of program:
The following figure shows a program that can specify Y010 as the CLEAR signal output device for Y000
(pulse output destination device):
M8000
RUN
monitor
4.3.5

Change in Logic of Near-Point (DOG) Signal (DSZR Instruction)

Turn on or off "DOG signal logic reverse" flag to specify the logic of the near-point (DOG) signal of DSZR
instruction (zero return instruction with DOG search function). Use the operand (
specify the near-point (DOG) signal.
Pulse output
destination device
Y000
Y001
Y002
*1
Y003
*1.
Devices related to Y003 (pulse output destination) are valid only if two FX
connected to the FX
4.3.6

Change in Logic of Zero-Phase Signal (DSZR Instruction)

Turn on or off "Zero point signal logic reverse" flag to specify the logic of the zero-phase signal of DSZR
instruction (zero return instruction with dog search function). Use the operand (
specify the zero-phase signal.
Pulse output
destination device
Y000
Y001
Y002
*1
Y003
*1.
Devices related to Y003 (pulse output destination) are valid only if two FX
connected to the FX
FNC 12
H0010
D8464
MOVP
M8464
M8341
→ For operation of DSZR instruction, refer to Section 6.2.
"DOG signal logic
reverse" flag
M8345
OFF:
M8355
ON:
M8365
M8375
PLC.
3U
→ For operation of DSZR instruction, refer to Section 6.2.
"Zero point signal
logic reverse" flag
M8346
OFF:
M8356
ON:
M8366
M8376
PLC.
3U
4.3 Various Flags for Operation Commands
Specifies the Y010 as the CLEAR signal output device for the
Y000 (pulse output destination device).
Turns on "CLEAR signal device designation function enable"
flag of the Y000 (pulse output destination device).
Turns on "CLEAR signal output enable" flag.
Description of setting
Positive logic (Turning on the input will turn on the near-
point signal.)
Negative logic (Turning off the input will turn on the near-
point signal.)
Description of setting
Positive logic (Turning on the input will turn on the zero-
phase signal.)
Negative logic (Turning off the input will turn on the zero-
phase signal.)
4 Before Programming
) of the instruction to
S
1
-2HSY-ADP adapters are
3U
) of the instruction to
S
2
-2HSY-ADP adapters are
3U
B - 39