Normal Running Status - Beko DRYPOINT RA III 1080 Translation Of Original Installation And Operation Manual

Compressed air refrigeration dryer
Table of Contents

Advertisement

DRYPOINT
®
RA III
9.4.1

Normal running status

INFORMATION
INFORMATION
Illustration
Dew point value
A dew point between 0 °C (+32 °F) and +10 °C (+50 °F) displayed on the User
Interface is considered to be correct according to the possible operating
conditions, e.g. flow rate, air inlet temperature, ambient temperature, etc.
Refrigerant compressor running
During the normal running status, the refrigerant compressor runs continuously.
The product must remain started during the entire compressed air usage time,
even if the air compressor works periodically.
Original installa�on and opera�on manual
Description / explanation
Normal running status
The User Interface shows:
the current date and time
Status ON with green background
the dew point temperature
61 | 120