Device Reset - Paradyne 7610 SNMP DSU User Manual

Snmp dsu
Hide thumbs Also See for 7610 SNMP DSU:
Table of Contents

Advertisement

Device Reset

7610-A2-GB20-10
Table 7-2. Loopbacks (2 of 2)
Loopback Type
Initiated By
Network-initiated
DDS Network
56 kbps DSU
Loopback (Non-
latching loopback)
Network-initiated
DDS Network
64 kbps CC DSU
Loopback
(Latching loopback)
Remote Digital
Remote unit sending
Loopback
V.54 sequence
V.54 Sequences to
ATI
remote unit
NMS
DTE via CT140
The DSU can be reset locally or remotely. From the Control menu, select Reset
Device and press Return. The DSU reinitializes itself, performing a Device
Self-Test. Refer to
Self-Test Results
Misconfiguring the DSU could make the user interface inaccessible, leaving it in a
state where an ATI session cannot be started through the Terminal port or via a
Telnet session. If this occurs, DSU connectivity can be restored with a terminal
that is directly connected and set for Terminal Port option defaults.
Two methods can be used to restore access to the ATI. Both methods cause a
device reset.
Reset Terminal Port – Allows you to only reset the configuration options
related to Terminal port usage. No security-related configuration options are
changed.
Reload Factory Defaults – Allows you to reload the Default Factory
Configurations, resetting all of the configuration areas and control settings for
security reasons. This method is useful when the user's passwords have
been forgotten.
November 1997
Notes
When IMC is enabled, the aggregate
data stream is looped back to the
network. Cannot be disabled by user.
Includes optional data scrambling and
uses 25-second timer to detect the
network sequence. When IMC is
enabled, the aggregate data stream is
looped back to the network. Can be
disabled by user.
Same as a DSU Loopback but initiated
by a remote unit via V.54 sequence.
When IMC is enabled, only user data is
looped back to the network. Can be
disabled locally. Refer to
Interface
Options, Table A-2.
Control via CT140 can be disabled.
Refer to
Data Port
Messages, Table 6-2.
Testing
Network
Options, Table A-3.
7-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

7610

Table of Contents