Linear Ball Bearings; Cleaning Agents / Lubricants; Transport And Storage - LinMot SM01-37 Installation Manual

Linear modules
Table of Contents

Advertisement

Installation Guide Linear Modules
Move the moving part of the guide back and forth several times so that the bearings are also degreased.
Repeat point 1.
Note: Disassembly of the guide or removal of the guide shafts from the bearings is generally not
necessary.
Grease the guide shafts carefully and completely with LU02 grease. Move the movable part of the guide
back and forth. Remove any grease that has been wiped off. There should only be a thin film of grease
on the guide shafts.

10.3.2 Linear Ball Bearings

First carry out cleaning instructions according to the section above.
Grease the bearing with 2-3 g of LU02 grease. A brush can be used to apply the grease evenly.
Important! Avoid overgreasing!
The guide shafts are inserted into the guide without lubrication.

10.4 Cleaning Agents / Lubricants

Depending on the degree of soiling and the requirements of the respective industry, different types of
cleaning are to be used. Starting with a dry wipe of the modules up to wet cleaning with foam cleaner. Due to
the variety of cleaning agents, concentrations and exposure times, no general statements can be made
regarding compatibility. If necessary, the resistance of the materials to chemicals must be checked under the
specific practical conditions. In particular, deviations in chemical resistance may occur at elevated
temperatures or in the case of interaction between individual chemicals.
However, the materials used in the SM01 modules (see chapter guarantee a high chemical resistance and
must be checked with the compatibility tables of the cleaning agents used.
Ordering information
Item
LU06-250
LU02-50
LU02-1000
* LinMot Spray LU06 is identical to KLÜBERFOOD NH1 4-002 (food grade UH1 approval).
** LinMot grease LU02 is identical with KLÜBERSYNTH UH1 14-31 (food grade UH1 approval).

11 Transport and Storage

LinMot linear modules may only be transported and stored in their original packaging.
The linear modules should not be removed from the packaging until they are installed.
The storage room must be dry, dust-free, frost-free and vibration-free.
The relative humidity should be less than 60 %.
Prescribed storage temperature: -15 °C...70 °C
The linear modules must be protected from extreme weather conditions.
The room air must not contain any aggressive gases.
Page 46 / 85
Description
Klüberfood NH1 4-002 Spray* (250 ml)
Lubricant for linear motors** (50 g)
Lubricant for linear motors** (1000 g)
SM01-37 / SM01-48
ENG
Item-No.
0150-2394
0150-1954
0150-1955
NTI AG / LinMot

Advertisement

Table of Contents
loading

Table of Contents