All connectors must not be connected or disconnected while DC voltage is present. Do not disconnect system components until all LinMot controllers LED’s have turned off. (Capacitors in the power supply may not fully discharge for several minutes after input voltage has been disconnected).
Controller Series E1031/2031/4031 V3 E1031 series Function and Wiring Motor Internal Linear Motor Hall Sensors Mot A ( addtional Motors B,C,D) 8 AT (E1031) Power Supply motor 2-Phase Powerstage (s) 16 AT (else) Emergency Stop Breaker PWR motor PWR+ AC-Mains PGND 72VDC (24..85VDC) - Circuit Breaker...
In order to assure a safe and error free operation, and to avoid severe damage to system components, all system components must be well grounded to either a single earth or utility ground. This includes both LinMot and all other control system components to the same ground bus.
Controller Series E1031/2031/4031 V3 Description of the connectors / Interfaces Power Supply Motor Supply 72VDC (24...85VDC) Internal Fuse 8AT E1001 PWR+ 16AT E2001/E4001 GND internally connected to PGND controller housing Optional: Regeneration Resistor (external) RR01-10/60 (10R, 60W) 72VDC (24..85VDC) Motor Supply - Tightening torque: min 0.4Nm - Screw thread: M 2,5 - Conductor cross section max.
Page 7
Do not connect or disconnect the motors from controllers with voltage present. Wait to connect or disconnect motors until all LinMot controller LED’s have turned off. (Capacitors may not fully discharge for several minutes after power has been turned off).Failure to observe these precautions may result in severe damage to electronic components in LinMot motors and/or controllers.
Page 8
Controller Series E1031/2031/4031 V3 Profibus Connector DSUB-9 (female) Isolated 5V output: max 50 mA NTI AG Installation: E1031/E2031/E4031 V3 series / 28.07.2010 Page 8/17...
Page 9
Controller Series E1031/2031/4031 V3 ME Control I/O Master Encoder Control I/O VCC ENC IN +5V ENC OUT GND ENC DIG IN 1 DIG IN 2 DIG IN 3 DIG IN 4 DIG IN 5 DIG IN 6 DIG IN 7 DIG IN 8 GND DIG IN VCC DIG OUT...
Controller Series E1031/2031/4031 V3 Mechanical Dimension Dimensions Fixings for 2 x M5 screws Centers dimensions in mm Recommended mounting for multiple controller installations dimensions in mm E1031 E2031 E4031 Single axes controller 2 axes controller 4 axes controller Width mm (in) 60 (2.4) Height mm (in)
Controller Series E1031/2031/4031 V3 Power Supply Requirement Power Supply motor The calculation of the needed power for the motor supply depends on the application and the used motor. The nominal supply voltage is 72 VDC. The possible range is from 24…85VDC. ATTENTION: The motor supply can rise up to 95 VDC when braking.
Controller Series E1031/2031/4031 V3 Error codes In the Error State the controller displays the error code by the 7-segment display: Code Description E0001 Missing or invalid parameter tree E0002 Missing or invalid application E0003 Controller type not supported E0004 MT command interface not available E0005 Timer watchdog error E0006...
Page 15
Controller Series E1031/2031/4031 V3 Code Description E0409 Drive D: Board Over Current E040A Drive D: Board Over Temperature E040B Drive D: AGND or 5VDC Fuse Blown $FFEC RAM error E1001 RTS: State is too long E1002 RTS: Controller version not supported E1003 RTS: Wrong firmware E1004...
Elkhorn, WI 53121 Sales and Administration: 877-546-3270 262-743-2555 Tech. Support: 877-804-0718 262-743-1284 Fax: 800-463-8708 262-723-6688 E-Mail: us-sales@linmot.com Web: http://www.linmot-usa.com/ ----------------------------------------------------------------------------------------------------------------------------- Please visit http://www.linmot.com/ to find the distribution near you. Smart solutions are… NTI AG Installation: E1031/E2031/E4031 V3 series / 28.07.2010 Page 17/17...