C-Connector; Pin Assignment Linear Modules Sm01-37 - LinMot SM01-37 Installation Manual

Linear modules
Table of Contents

Advertisement

Installation Guide Linear Modules
Ordering information
Item
MC01-R/f-IP69K-SSC

6.2.2 C-Connector

Ordering information
Item
MC01-C/f-IP69K-SSC

6.2.3 Pin Assignment Linear Modules SM01-37

Do not connect or disconnect motor when there is power on the servo drive.
Use only double-shielded original LinMot cable. Cables from other sources must be
checked precisely before commissioning.
Incorrect connections can destroy the drive and stator.
Connector Type
Phase1+
Phase1-
Phase2+
Phase2-
+5V
SIGNAL-GROUND*
Sensor Sin
Sensor Cos
Temp sensor
SHIELD** of stator and stator cable
Connector on the stator
(-cables)
Extension cables are double shielded. The two shields of the extension cables must not be
connected together: the inner shield of the extension cables is used as GROUND and must
be connected to SIGNAL-GROUND*; only the outer shield must be connected to SHIELD**
of the connector.
NTI AG / LinMot
Description
Motor Connector R/f, IP69k, SSC
Protection class: IP69k
Material: Stainless steel (1.4404)
Max. torque: 0.6 Nm
Description
Motor connector C/f, IP69k, SSC
SM01-37 / SM01-48
Item-No.
0150-3347
Item-No.
0150-3306
R-Connector
Pin
1
2
3
4
A
B
C
D
E
Case
ENG
Page 23 / 85

Advertisement

Table of Contents
loading

Table of Contents