eBOX671B Series user's Manual
BIOS menu item
Activate Voltage Trigger
Low Voltage Trigger
Shutdown Delay Timer (Low
Voltage)
IGN Trigger
56
Description
The system only turns on when the voltage delivered by the power
source is higher than the value you set here.
The system will begin countdown stage once voltage drops below
the value you set here.
If the power source voltage does not come back above the value of
[Activate Voltage Trigger] within the time you set for [Shutdown
Delay Time (Low Voltage)], the system will shut down and remain
off.
The counter will be activated once power source voltage drops
below the value defined in [Low Voltage Trigger]. The system will be
forced to turn off once timer completes countdown.
Enable
[System Turn On Delay] and [Shutdown Delay] will be trigged by
IGN.
Disable
IGN signal will not affect any power management.
BIOS Setup Utility
Need help?
Do you have a question about the eBOX671B Series and is the answer not in the manual?
Questions and answers