Watson-Marlow 100 Series Manual
Hide thumbs Also See for 100 Series:

Advertisement

Watson-Marlow 120 IP31 pumps
WATSON-MARLOW MANUALS
m-120coversheet-F-114DV-gb-03 Original instructions
Watson-Marlow 120 cased pumps
120F/DV
Contents
1
General information
2
Operating manual
3
114DV pumphead
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Watson-Marlow 100 Series

  • Page 1 WATSON-MARLOW MANUALS m-120coversheet-F-114DV-gb-03 Original instructions Watson-Marlow 120 cased pumps 120F/DV Contents General information Operating manual 114DV pumphead Watson-Marlow 120 IP31 pumps...
  • Page 2: Table Of Contents

    1.11 Start-up check list Information for returning pumps 3 1.12 Drive maintenance Peristaltic pumps - an overview 4 1.13 Drive spares Safety notes and standards 1.14 Decontamination certificate Good pump installation practice 7 1.8.1 General recommendations 7 Watson-Marlow 120 IP31 pumps: general information...
  • Page 3: Declaration Of Conformity

    No 61010-1. Conforms to UL 61010-1. than in normal operation as defined in this pump manual. Watson-Marlow shall not be liable for any loss, dam- 1.2 Declaration of age, or expense directly or indirectly related to or arising out of the use of its products, including dam-...
  • Page 4: When You Unpack Your Pump

    Check against the components sup- If you wish to return a pump for service or other plied list. reasons, contact Watson-Marlow or your distribu- tor, quote your pump’s serial number, and ask for Packaging disposal a returns number. Include this number when you ship the pump.
  • Page 5: Peristaltic Pumps - An Overview

    At the same time, a new partial vacuum is cre- ated behind the second roller into which more fluid is drawn from the inlet port. Watson-Marlow 120 IP31 pumps: general information...
  • Page 6: Safety Notes And Standards

    Do not fit any devices to the drive unit other than those tested and approved by Watson-Marlow. Doing so could lead to injury to persons or damage to property for which no liability can be accepted.
  • Page 7 Power supply standards UL 60950-1 Safety standards CSA-C22.2 TUV EN 60950-1 EN 55022 Class B, FCC part 15/CIS PR 22 Class B EN 61000-3-2, 3 EN61000-4-2, 3, 4, 5, 6, 8 and 11 Criteria A Watson-Marlow 120 IP31 pumps: general information...
  • Page 8: Good Pump Installation Practice

    You can place other equip- ment on the pump’s upper surface as long as the ambient temperature does not exceed 40C. Watson-Marlow 120 IP31 pumps: general information...
  • Page 9: Do's And Do Not's

    If in doubt about the compatibility of a tube material 120U+400D1 shown here. and the duty fluid, request a Watson-Marlow tube 120U+400DM2 sample card for immersion trials. 120U+400DM3 1.8.2 Do’s and do not’s Do not build a pump into a tight location without adequate airflow around the pump.
  • Page 10: Power Supply

    100 starts per hour. A minimum interval of 3 seconds is required between power cycles. Euro We recommend using com- mercially available supply voltage surge suppression where there is excessive electrical noise. Watson-Marlow 120 IP31 pumps: general information...
  • Page 11: Dimensions

    Tools, wires etc with a vertically. No harmful thickness of more than effect must be produced 2.5mm are prevented from approach 120 pump drive with 120 pump drive with 400DM2 pumphead 400DM3 pumphead Watson-Marlow 120 IP31 pumps: general information...
  • Page 12: Start-Up Check List

    There are no user-serviceable parts inside the pump. The unit should be returned to Watson- Marlow or its appointed agents or distributors for service. 1.13 Drive spares Dedicated external DC power supply unit and plug adaptors: MN2634B Foot: FB0012 Watson-Marlow 120 IP31 pumps: general information...
  • Page 13: Decontamination Certificate

    I understand that the personal data collected will be kept confidentially in accordance with the UK Data Protection Act 1998. RGA number Signature Your position Date Please print out, sign and fax to Watson-Marlow Pumps at +44 1326 376009. Watson-Marlow 120 IP31 pumps: general information...
  • Page 14 Section 2 of 3: Operating manual Contents 2.1 Pump specifications 2.2 Good pump installation practice 4 2.3 Switching the pump on 2.4 Operation 2.4.1 Start and stop 2.5 Performance data 2.6 Error codes 2.7 Troubleshooting Watson-Marlow 120F IP31 pumps: operating instructions...
  • Page 15: Pump Specifications

    A nameplate is fixed to the rear of the pump. It contains manufacturer and contact details, product reference number, serial number and model details. 120F This pump is started and stopped from the keypad. Watson-Marlow 120F IP31 pumps: operating instructions...
  • Page 16 Storage temperature range -25C to 65C, -13F to 149F Maximum altitude 2,000m, 6,560ft Humidity (non-condensing) 80% up to 31C, 88F, decreasing linearly to 50% at 40C, 104F Weight See Section 1, General information Noise <60dB(A) Watson-Marlow 120F IP31 pumps: operating instructions...
  • Page 17: Good Pump Installation Practice

    * If the pump is isolated from mains power while it is running, it will start when power is re-connected: The pump is now ready to operate according it is not necessary to press START. to the default settings. Watson-Marlow 120F IP31 pumps: operating instructions...
  • Page 18: Operation

    Slow flashing— ½ second on, ½ second off—indicates a fault which requires the pump to be returned to your local ser- vice centre. Watson-Marlow 120F IP31 pumps: operating instructions...
  • Page 19: Troubleshooting

    Check that any valves in the lines are open. Check that the rotor is in the pumphead, that it rotates and that the rollers are in good condition. Check that fluid is supplied to the pump. Watson-Marlow 120F IP31 pumps: operating instructions...
  • Page 20 114DV continuous tubing pressure and viscosity product codes 114DV pumphead installation 3.10 Trademarks Tube holder positioning 3.11 Do not use pumps in patient- 3.5.1 Tube holder connected applications repositioning 3.12 Publication history Tube loading and removal Watson-Marlow 114DV pumphead: operating instructions...
  • Page 21: 114Dv Safety Information

    Watson-Marlow 114DV pumphead: operating instructions...
  • Page 22: 114Dv Pumping Conditions: Pressure And Viscosity

    Watson-Marlow 114DV pumphead: operating instructions...
  • Page 23: Tube Holder Positioning

    The outer setting will optimise flow rate but the risk of tube slip is increased. The tube holder is factory pre-set to the outer position. Outer position, for large tubing Inner position, for small tubing Watson-Marlow 114DV pumphead: operating instructions...
  • Page 24: Tube Holder Repositioning

    Note: The pictures on the previous page show the tube holders’ correct positions for small and large tubing. If a tube holder is not vertical relative to the body of the pumphead, it is wrongly positioned. Follow the instructions above to reposition it. Watson-Marlow 114DV pumphead: operating instructions...
  • Page 25: Tube Loading And Removal

    The track closes automatically and the tube is stretched correctly as it does l To remove the tube, reverse the sequence. 3.7 114DV pumphead spares Click! 114DV pumphead with tube 013.6000.00A holder pre-set into larger bore setting Watson-Marlow 114DV pumphead: operating instructions...
  • Page 26: 3.8 114Dv Performance Data

    (bar) pressure (bar) Marprene tubing, 1.6mm wall, 100 rpm, CCW rotation. Note: The 120S and the 120U must be run counter-clockwise to achieve pressures up to 2 bar. The 120F is a transfer-only, 0 bar pump. Watson-Marlow 114DV pumphead: operating instructions...
  • Page 27: 114Dv Continuous Tubing

    960.0048.016 965.0048.016 3.10 Trademarks 3.12 Publication history Bioprene, Marprene, Pumpsil and Watson- Marlow are trademarks of Watson-Marlow Limited. m-114pumphead for 120-gb-03: GORE STA-PURE PCS and GORE STA-PURE PFL Watson-Marlow 114 pumphead. are trademarks of W.L.Gore and Associates. First published 07 10. Revised 08 15.

This manual is also suitable for:

120120u120f120f/dv

Table of Contents