Unit Specifications - Omron NXR Series User Manual

Environment-resistive remote terminal
Hide thumbs Also See for NXR Series:
Table of Contents

Advertisement

Item
Topology
Transmission media
Transmission distance
Noise immunity
Node address setting method
*3
Node address range
Indicators
Process data
PDO size/node
Mailbox
Synchronization type
*1.
The IO-Link Master Unit conforms to the EtherCAT standards. Confirm the specifications of the connected EtherCAT
master for the supported topology. Note that the IO-Link Master Unit supports the ring topology.
*2.
For the ring topology, the minimum value of the supported communications cycle is 125 µs. Allowing the IO-Link Mas-
ter Unit to operate with a shorter communications cycle than the minimum value may cause the loss of EtherCAT com-
munications frames or a communications stop.
*3.
The setting range of the node address depends on the specifications of the connected EtherCAT master. Check the
specifications of the EtherCAT master for the supported node address setting range of the EtherCAT master.
2-1-3

Unit Specifications

Item
Unit name
Model
IO-Link
IO-Link connector
specifica-
type
tions
Communications
protocol
Number of ports
Baud rate
Topology
Compliant stand-
ards
Cable specifica-
tions
Unit/input power supply voltage
Output power supply voltage
Maximum power supply current
NXR-series IO-Link Master Unit for EtherCAT User's Manual (W640)
2 Specifications and Application Procedures
Depends on the specifications of the EtherCAT master
Category 5 or higher twisted-pair cable (Recommended cable: double-
shielded cable with aluminum tape and braiding)
Distance between nodes (slaves): 50 m or less
Conforms to IEC 61000-4-4, 1 kV or more
Setting with hexadecimal ID switch or Configuration Software
Setting with hexadecimal ID switch: 01 to FF hex (1 to 255)
Setting with Configuration Software: 0001 to FFFF hex (1 to 65,535)
L/A IN (Link/Activity IN) × 1
L/A OUT (Link/Activity OUT) × 1
RUN × 1
ERR × 1
Variable PDO mapping
Input: 1 to 270 bytes
Output: 2 to 258 bytes
Emergency messages, SDO requests, and SDO responses
Free-Run Mode
IO-Link Master Unit
NXR-ILM08C-ECT
Class A
IO-Link protocol
8
COM1: 4.8 kbps
COM2: 38.4 kbps
COM3: 230.4 kbps
1:1
IO-Link Interface and System Specification Version1.1.2
IO-Link Test Specification Version1.1.2
Cable type: Unshielded
Cable length: 20 m max.
Electrostatic capacity between lines: 3 nF max.
Loop resistance: 6 Ω max.
24 VDC (20.4 to 26.4 VDC)
24 VDC (20.4 to 26.4 VDC)
9 A
Sum of Unit/input power supply current and output power supply current
Specification
*1*2
Specification
2
2-3