Omron NXR Series User Manual page 159

Environment-resistive remote terminal
Hide thumbs Also See for NXR Series:
Table of Contents

Advertisement

Bit
Data name
12
Port7 Pin4
When the Port7 Pin4 Communications Mode Setting is SIO (DI) Mode
Digital Input
Digital Input Data from pin 4 of port 7.
Bit
TRUE:
The Port7 Pin4 Digital Input Bit is ON.
FALSE:
The Port7 Pin4 Digital Input Bit is OFF.
When the Port7 Pin4 Communications Mode Setting is IO-Link Mode and the Offset Setting of
Port7 Digital Input Data Collection is correct
TRUE:
In the Por7 IO-Link Input Data, the input bit in the specified offset position is ON.
FALSE:
In the Port7 IO-Link Input Data, the input bit in the specified offset position is OFF.
13
Port7 Pin2
When the Port7 Pin2 Communications Mode Setting is SIO (DI) Mode
Digital Input
Digital Input Data from pin 2 of port 7.
Bit
TRUE:
The Port7 Pin2 Digital Input Bit is ON.
FALSE:
The Port7 Pin2 Digital Input Bit is OFF.
14
Port8 Pin4
When the Port8 Pin4 Communications Mode Setting is SIO (DI) Mode
Digital Input
Digital Input Data from pin 4 of port 8.
Bit
TRUE:
The Port8 Pin4 Digital Input Bit is ON.
FALSE:
The Port8 Pin4 Digital Input Bit is OFF.
When the Port8 Pin4 Communications Mode Setting is IO-Link Mode and the Offset Setting of
Port8 Digital Input Data Collection is correct
TRUE:
In the Port8 IO-Link Input Data, the input bit in the specified offset position is ON.
FALSE:
In the Port8 IO-Link Input Data, the input bit in the specified offset position is OFF.
15
Port8 Pin2
When the Port8 Pin2 Communications Mode Setting is SIO (DI) Mode
Digital Input
Digital Input Data from pin 2 of port 8.
Bit
TRUE:
The Port8 Pin2 Digital Input Bit is ON.
FALSE:
The Port8 Pin2 Digital Input Bit is OFF.
PDO Entry Assigned to New Messages Available Information
Indicates the new messages available. This notification indicates the update of the error log.
Using the New Messages Available notification to the EtherCAT master as a trigger, you can check
errors that occurred in the IO-Link Master Unit by reading the Diagnosis History (10F3 hex) CoE object
of the IO-Link Master Unit from the EtherCAT master.
This allows you to use this manual to view and correct errors.
NXR-series IO-Link Master Unit for EtherCAT User's Manual (W640)
7 Setting Up IO-Link Master Unit
Description
I/O port
name
Port7 Pin4
Digital Input
Bit
Port7 Pin2
Digital Input
Bit
Port8 Pin4
Digital Input
Bit
7
Port8 Pin2
Digital Input
Bit
7-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxr-ilm08c-ect

Table of Contents