8.4

Managing the expert settings

8.4.1

Managing customer-specific limits

The "Customer-specific limits" menu is intended to manage limits for manual tests and
customer-specific test procedures.
Requirements
• You are logged on to the device as a user with admin status.
Menu
"Settings > System settings > Customer-specific limits"
Procedure
1. Select the desired limit. To do this, tap the right of the line.
A selection of test standards is displayed.
2. Select the corresponding standard. To do this, tap the right of the line.
An input window opens.
3. Edit the limit and confirm your entries with the "Enter" button.
4. Save your entries. To do this, tap the "Save" button.
Result
The limits for the manual test are stored temporarily, until the device is restarted.
To reset the temporarily changed limits to the default values, tap the "Reset" button.
To permanently save the changed limits as new default limits for manual and customer-specific
test procedures, tap the "Overwrite" [} page 28] button.