11

Technical data

Protection class II
Contamination level
Protection category
(DIN VDE 0470-1, IEC / EN 60529)
Overvoltage category
Mains connection
Current consumption
Maximum load of the test socket
Maximum pre-fuse
Housing
Housing dimensions
(length x width x height)
Weight
Display dimensions
EMC
Max. barometric altitude
Operating temperature
Max. relative air humidity
Operating conditions
Storage
(remove the batteries from the device)
Ambient temperature
Max. relative air humidity (linearly decreasing,
non-condensing)
Table 28: Technical data
100
(as the protective conductor for the test socket
is looped through)
2
• IP 40 (with the cover being open)
• IP 67 (with the cover being closed)
CAT II
115 ... 230 V‑AC ±10 %, 50 ... 60 Hz
• Without test socket: 0.3 A
• With test socket: 16 A
16 A
16 A
Device case
170 mm x 410 mm x 350 mm
6 kg
115 mm x 87 mm
EN 61557‑16, EN 61326‑1, EN 61326‑2‑2
2 000 m
0 ... 35 °C (do not permanently expose the
device to sunlight)
80 % RH (0 ... 40 °C), non-condensing
To be used inside buildings in dry
environments
-20 ... 60 °C (do not permanently expose the
device to sunlight)
80 % at 30 °C
60 % at 40 °C
BENNING ST 755+ / ST 760+
Technical data
10.6 Recovering the password
5284 / 08/2023 en