8 | Water connection
(B) Activated carbon filter
In the case of strong chlorination (Cl
sponds to 0.2 ppm), an activated carbon filter must be installed upstream. In-
formation on the chlorination (Cl
company.
(C) Reverse osmosis system
If the chloride concentration (Cl
sis system must be installed due to the risk of corrosion. Information about the
chloride concentration (Cl
pany.
Malfunction due to falling below the minimum conductivity value
Make sure that the minimum conductivity of the water is 50 μS/cm [32
ppm TDS].
(D) Water softening
iCombi Pro / iCombi Classic
When used according to instructions, iCombi Pro / iCombi Classic units re-
move the limescale themselves. Upstream water softening for scale is not nec-
essary.
CombiMaster Plus without care
Water softening is recommended for water treatment in the event of very
n
strong calcification (without chloride contamination).
Set a weakly acidic decarbonization via a hydrogen ion exchanger (H
n
Sodium ion exchangers (salt water) (as are common in dishwashers) are
not recommended.
Phosphate dosing is not recommended because of its negative effect on
n
the water system.
Notes on connecting the water filter
The diameter of the water hose must be at least 1/2 inch ID, to the water filter
at least 3/4 inch ID.
When using a combination of water filters, observe the order of the filters in
the flow direction:
(A)-(B)-(C)
n
Or
(A)-(B)-(D)
n
72 / 100
) of the water above 0.2 mg/l (corre-
2
) can be obtained from the local water supply
2
-
) is above 80 mg/l [80 ppm], a reverse osmo-
-
) can be obtained from the local water supply com-
NOTE
80.06.083_iCombiPro-iCombiClassic_IM_en-US
+
).