Safety Notes On Gas Units - Rational iCombi Pro Original Installation Instructions

Table of Contents

Advertisement

The unit should only be set up in a protected environment
n
safe from frost and wind.
Do not set up the unit in adverse weather conditions, such
n
as rain.
The unit should only be connected in accordance with the
n
installation manual and the information on the type plate.
Switch off the unit when disconnecting it from or connect-
n
ing it to the power supply.
After use, only transport the unit in ambient temperatures
n
of over 0°C [32 F].
Only store the unit in ambient temperatures of over 0°C
n
[32 °F].
Do not operate the unit without an air filter.
n
Do not spray aerosols in the area around the unit while the
n
unit is in operation.
Check the unit for damage during transport. Inform your
n
specialist dealer/shipping company immediately if you
suspect transport damage.

2.3 Safety notes on gas units

Harmful flue gases
There is a danger of suffocation if the concentration of harmful
flue gases is not vented.
Make sure that the installation area provides sufficient ven-
n
tilation.
Always carry out a flue gas analysis when commissioning
n
gas units.
If an extractor hood is used, make sure that the extractor
n
hood is turned on for gas operation.
Do not place any objects on the flue gas pipes.
n
Do not block the area around the extraction of combustion
n
air with objects.
80.06.083_iCombiPro-iCombiClassic_IM_en-US
2 | Safety
11 / 100

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iCombi Pro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Icombi classicCombimaster plus

Table of Contents