2. Use a suitable gas leak detector to check the gas supply and gas distribution
on the unit for leaks.
10.3 Gas consumption by gas type
Natural gas EK G25.3 Netherlands
Required connection
flow pressure (mbar)
Wobbe index (MJ/
m³) Wi
Wobbe index (MJ/
m³) Ws
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
Natural gas G20 USA (North America)
Required connection
flow pressure (mbar)
Wobbe index (MJ/m³)
Wi
80.06.083_iCombiPro-iCombiClassic_IM_en-US
6 half
6 full
size
size
20-30
20-30
38.49
38.49
42.71
42.71
1.56
3.37
m³/h
m³/h
13 kW
28 kW
6 half
6 full
size
size
6.5-10.
6.5-10.
0 in/wc
0 in/wc
45.67
45.67
10 | Gas connection for gas units
10 half
10 full
size
size
20-30
20-30
38.49
38.49
42.71
42.71
2.65
4.81
m³/h
m³/h
22 kW
40 kW
10 half
10 full
size
size
6.5-10.
6.5-10.
0 in/wc
0 in/wc
45.67
45.67
20 half
20 full
size
size
20-30
20-30
38.49
38.49
42.71
42.71
5.05
9.63
m³/h
m³/h
42 kW
80 kW
20 half
20 full
size
size
6.5-10.
6.5-10.
0 in/wc
0 in/wc
45.67
45.67
83 / 100