Local Upgrade Of Inverter Software Version - Goodwe XS Series User Manual

Grid-tied pv inverter
Hide thumbs Also See for XS Series:
Table of Contents

Advertisement

User Manual V1.1-2023-12-30
Parameters
PvShadowMPPT
PvTimeInterval
SetSunspec
ARC Enable
ARC SelfCheck
ARC FaultClear
Set Password
ViewFaults
ClearFaults

8.3 Local Upgrade of Inverter Software Version

Step 1: Contact the after-sales service center to obtain the inverter software upgrade package.
Step 2: Store the upgrade package in the USB flash drive.
Step 3: Insert the USB flash drive into the inverter USB interface, and upgrade the inverter
software version according to the interface prompts.
Description
Enable the shadow scan function if the PV panels are shadowed.
Set the scan time according to the actual needs.
Set the Sunspec based on the actual communication method.
ARC is optional and off by default. Enable or disable ARC accordingly.
Check whether ARC can work normally.
Clear ARC alarm records.
The password can be changed. Keep the changed password in mind
after changing it. Contact the after-sales service if you forget the
password.
Check historical error message records of the inverter.
Clear historical error message records of the inverter.
39
System Commissioning

Advertisement

Table of Contents
loading

Table of Contents