NS SERIES USER MANUAL
SOLAR INVERTER

Advertisement

loading

Summary of Contents for Goodwe GW1000-NS

  • Page 1 Official Website Company Wechat NS SERIES USER MANUAL SOLAR INVERTER...
  • Page 2: Table Of Contents

    1 Symbols ................01 2 Safety ..................01 3 Installation 3.1 Mounting Instructions ......02 3.2 Inverter Overview and Package ....02 3.3 Inverter Installation ......03 3.4 Electrical Connection ......05 4 System Operation 4.1 Indicator Lights ........08 ..
  • Page 3: Mounting Instructions

    Snow Lay up 2 Safety The NS series inverter of Jiangsu GoodWe Power Supply Technology Co. Ltd. (hereinafter referred to as GoodWe) strictly conforms to 3.2 Inverter Overview and Package related safety rules in design and test. Safety regulations relevant to the location shall be followed during installation, Check the scope of delivery for completeness and any visible damage.
  • Page 4: Inverter Installation

    To allow dissipation of heat, and for convenience of dismantling, clearances around the inverter must be at least: 3.2.2 Package 00mm Upward ----------300mm Wall-mounted 200mm 200mm 300mm Inverter×1 DC PlugX1pair *Branch Socket ×1pair Downward--------500mm Bracket×1 Front-------------300mm Both sides---------200mm 00mm Antenna×1 Wi-Fi Connection Figure 3.3.1-2 Guide×1...
  • Page 5: Electrical Connection

    (5)Don't connect positive or negative pole of PV string to PE wire. Otherwise, it will cause damage to inverter. Installation instruction of the DC connector refer to Figure 3.4.2-1. Figure 3.4.3-1 If you need USB monitoring solution, please download EzExplorer software at www.goodwe.com.cn.
  • Page 6: Indicator Lights

    Configuration in the accessory box. The RS-485 interface is used to connect EzLogger, and the maximum total length of all connecting cables should not exceed 800m. After configuration, please browse http://www.goodwe-power.com to create PV station. RS-485 connection is referred to 3.4.4-1.
  • Page 7: Error Code

    First Level Menu Second Level Menu (3) Use of the display Long press 2S Status Display Lock There are 2 modes of button operation: Short press and long press. Short press (4) Use of the display and LCD display Long press 2S E-Today= 15.2KWh The display allows accessing the configuration of the basic parameters.
  • Page 8: Troubleshooting

    5 Troubleshooting the time after 20 seconds without any key operation, and the LCD will automatically return to the main menu and the backlight will switch off. In most situations, the inverter requires very little maintenance. However, if the inverter is not working properly, please try the ●Set protocol: following troubleshooting solutions: The function is only used for service personnel, set wrong protocol could lead to communication failure.
  • Page 9: Technical Parameters

    Display Troubleshooting Model GW1000-NS GW1500-NS GW2000-NS GW2500-NS GW3000-NS Protection SPI Fail 1.Disconnect the DC connector. Inverter Residual current monitoring unit Integrated 2.Reconnect the DC connector. DC Bus High failure Anti-islanding protection Integrated 3.If the problem still exits, please call the local service office.
  • Page 10 Moisture location category definition Level Moisture parameters 4K4H Temperature Range 0~+40℃ -33~+40℃ -20~ +55°C Humidity Range 5%~85% 15%~100% 4%~100% Environment category definition Outdoor : the ambient air temperature is -20~50°C, Relative humidity range is 4 % to 100 %, applied to PD3 Indoor unconditioned: the ambient air temperature is -20~50°C, Relative humidity range is 5 % to 95%,applied to PD3 Indoor conditioned: the ambient air temperature is 0~40°C, Relative humidity range is 5 % to 85%,applied to PD2 Pollution degree definition...