Goodwe XS Series User Manual page 50

Grid-tied pv inverter
Hide thumbs Also See for XS Series:
Table of Contents

Advertisement

Maintenance
No.
Fault
LVRT
10
Undervoltage
HVRT
11
Overvoltage
30mAGfci
12
Protection
60mAGfci
13
Protection
150mAGfci
14
Protection
Abnormal
15
GFCI
Large DC of
16
AC current L1
Large DC of
17
AC current L2
Cause
Utility grid exception. The
duration of the utility grid
exception exceeds the set
time of LVRT.
Utility grid exception. The
duration of utility grid
exception exceeds the set
time of HVRT.
The input insulation
impedance becomes
low when the inverter is
working.
The DC component of the
output current exceeds
the safety range or default
range.
User Manual V1.1-2023-12-30
Solutions
1. If the problem occurs occasionally,
the utility grid may be abnormal
temporarily. The inverter will recover
automatically after detecting that the
utility grid is normal.
2. If the problem occurs frequently,
check whether the grid frequency is
within the permissible range. If not,
contact the local power company. If
yes, contact the dealer or the after-
sales service.
1. If the problem occurs occasionally, it
may be caused by a cable exception.
The inverter will recover automatically
after the problem is solved.
2. Check whether the impedance
between the PV string and PE is too
low if the problem occurs frequently
or persists.
1. If the problem is caused by an
external fault like a utility grid
exception or frequency exception,
the inverter will recover automatically
after solving the problem.
2. If the problem occurs frequently and
the PV station cannot work properly,
contact the dealer or the after-sales
service.
46