Goodwe XS Series User Manual

Goodwe XS Series User Manual

Solar inverter
Hide thumbs Also See for XS Series:

Advertisement

SEMS Portal App
LinkedIn
Company's Offical
Website
GOODWE (Germany)
Fürstenrieder Str. 279a 81377 München, Germany
T: +49 8974120210 +49 421 83570-170 (service)
sales.de@goodwe.com
service.de@goodwe.com
GOODWE (Netherlands)
Franciscusdreef 42C, 3565AC Utrecht, the Netherlands
T: +31 (0) 30 737 1140
sales@goodwe.com
service.nl@goodwe.com
GOODWE (India)
1202, G-Square Business Park, Sector 30A, Opp. Sanpada
Railway Stn., Vashi, Navi Mumbai- 400703
T: +91 (0) 2249746788
sales@goodwe.com / service.in@goodwe.com
GOODWE (Turbutton)
Adalet Mah. Megapol Tower K: 9 No: 110 Bayraklı - Izmir
T: +90 (232) 935 68 18
info@goodwe.com.tr
service@goodwe.com.tr
GOODWE (Mexico)
Oswaldo Sanchez Norte 3615, Col. Hidalgo, Monterrey,
Nuevo Leon, Mexico, C.P. 64290
T: +52 1 81 2871 2871
sales@goodwe.com / soporte.latam@goodwe.com
Note: The information above is subject to change without prior notice, for details refer to
www.goodwe.com
340-00414-01
GOODWE (China)
No. 90 Zijin Rd., New District, Suzhou, 215011, China
T: +86 (0) 512 6958 2201
sales@goodwe.com (sales)
service@goodwe.com (service)
GOODWE (Brazil)
Rua Abelardo 45, Recife/PE, 52050-310
T: +55 81 991239286
sergio@goodwe.com
servico.br@goodwe.com
GOODWE (UK)
6 Dunhams Court, Dunhams Lane, Letchworth
Garden City, SG6 1WB UK
T:+ 44 (0) 333 358 3184
enquiries@goodwe.com.uk / service@goodwe.com.uk
GOODWE (Italy)
Via Cesare Braico 61, 72100 Brindisi, Italy
T: +39 338 879 38 81; +39 831 162 35 52
valter.pische@goodwe.com (sales)
operazioni@topsenergy.com; goodwe@arsimp.it (service)
GOODWE (Australia)
Level 14, 380 St. Kilda Road, Melbourne,
Victoria, 3004, Australia
T: +61 (0) 3 9918 3905
sales@goodwe.com / service.au@goodwe.com
GOODWE (Korea)
8F Invest Korea Plaza, 7 Heoleung-ro
Seocho-gu Seoul Korea (06792)
T: 82 (2) 3497 1066
sales@goodwe.com / Larry.Kim@goodwe.com
XS SERIES USER MANUAL
SOLAR INVERTER
Version 1.0.2

Advertisement

Table of Contents
loading

Summary of Contents for Goodwe XS Series

  • Page 1 GOODWE (China) No. 90 Zijin Rd., New District, Suzhou, 215011, China T: +86 (0) 512 6958 2201 sales@goodwe.com (sales) service@goodwe.com (service) XS SERIES USER MANUAL GOODWE (Germany) GOODWE (Brazil) Fürstenrieder Str. 279a 81377 München, Germany Rua Abelardo 45, Recife/PE, 52050-310...
  • Page 2: Table Of Contents

    1 Symbols ..........................2 Safety Measures & Warning ............... 3 Product Introduction ..................3.1 Inverter Overview ........................04 3.2 Package ............................05 4 Installation ........................4.1 Mounting Instructions ....................... 06 4.2 Equipment Installation ......................06 4.3 Electrical Connection ........................ 08 4.4 Communication Connection ....................
  • Page 3: Symbols

    GOODWE's instructions and avoid actions that put lives at risk. The PV modules should have as a minimum an IEC61730 class A rating protection. • If the equipment is used in a way not authorized by the GOODWE, the equipment built-in protec- Keep Dry tions may be damaged.
  • Page 4: Product Introduction

    1. DC Switch (Optional) To our inverter product, GOODWE provides standard manufacture warranty which comes with the 2. PV Input Terminals 2 3 4 5 product and prepaid warranty extension solution to our customer.
  • Page 5: Package

    4 Installation 3.2 Package The unit is thoroughly tested and strictly inspected before delivery. Damage may still occur 4.1 Mounting Instructions during shipping. 1. In order to achieve optimal performance, the ambient temperature should be lower than 45℃. 1. Check the package for any visible damage upon receiving. 2.
  • Page 6: Electrical Connection

    1. When connecting the inverter make sure to adjust the voltage and the frequency in compliance sake of heat dissipation and demounting. with the grid regulations and the specifications of the GOODWE. 2. Add a breaker or fuse to the AC side. Please note that the specification should be more than 1.25 300mm times of rated AC output current.
  • Page 7 6. Red represents positive, black represents negative. 7. For the XS series the minimum insulation resistance to the ground of the PV panels must exceed 16.7kΩ (R=500/30mA). There is risk of shock hazard if this minimum resistance...
  • Page 8: Communication Connection

    Please refer to "Wi-Fi Configuration Instruction" in the accessory box for detailed instruction. Please follow the steps below to connect "PE" cable to ground. The WiFi module installation of XS series are shown as below. Step 1 Strip the wire insulation sheet of a suitable length with a wire stripper.
  • Page 9 Put the cable through the connector and connect to the terminal. cation function is required. RS485 communication connection of XS series are shown as below. For single inverter connection Please connect RS485 cables to 'RS485-' port (3 or 7) and 'RS485+'...
  • Page 10 Remote shutdown is only for Europe installations, in compliance with European safety require- 25mm Content - ments. And Remote shutdown device is not provided by GOODWE. Detailed operation is shown as below: Step 1 Dismantle the resistor or shortcircuit cable.
  • Page 11: System Operation

    OFF = No fault 4.4.5 Earth Fault Alarm In compliance with the section 13.9 of IEC62109-2, the XS series inverter is equipped with an earth 5.2 User Interface And Syetem Configuration fault alarm. When earth fault occurs, the fault indicator at the front LED screen will light up. On inverters with Wi-Fi communication, the system sends an email with the fault notification to the...
  • Page 12 Normal First Level Menu Second Level Menu Normal Long Press Pac=XXXX.XW 50Hz Grid Default Pac=2595.5W Short Press Display area is divided as follows: E-Today=15.2KWh Long Press Lock Pac=2595.5W Line ① Short Press E-Total=533.17KWh Line ② Pac=2595.5W Short Press Long Press No Error Vpv=325.2/325.5V 5.2.4 Display Area...
  • Page 13 • Short press the button to enter the "Ipc" menu which displays the PV current in "A". "Set Protocol Display" menu. Long press the button to enter sub menu. The circulatory sub menu including two protocols can be found. The protocol can be chosen by short pressing the •...
  • Page 14: Error Message

    • Modify Password: If sub test finishes and LCD displays "Test ***** Ok", inverter relay breaks off and reconnect to grid automatically according to CEI 0-21 requirement. Then the next test starts. Long press the button to enter password change menu. Short press to increase the number in current location, long press to move the cursor to next position.
  • Page 15: Precaution For Initial Startup

    Short press the button until the LCD displays "Wi-Fi Reload", then long press the button until the PF Power Curve Mode LCD displays "Wi-Fi Reloading�". Stop pressing and wait for the screen to display "Wi-Fi Reload Function Default value (Australia) Default value (New Zealand) Setting range OK"...
  • Page 16: Troubleshooting

    6 Troubleshooting 5.6.3 QU Curve Mode If the Inverter is not able to work properly, please refer to the following instructions before QU curve mode can be modified by Calibrate communication, according to the set range to set contacting your local service. If any problems arise, the red (FAULT) LED indicator on the front the corresponding value.
  • Page 17: Technical Parameters

    7 Technical Parameters Type of fault Troubleshooting Relay-Check Failure Technical Data GW700-XS GW1000-XS GW1500-XS PV String Input Data DCI Injection High Max. DC Input Power (W) 1300 1950 Max. DC Input Voltage (V) EEPROM R/W Failure MPPT Range (V) 40~450 40~450 50~450 SCI Failure...
  • Page 18 Note: Technical Data GW2000-XS GW2500-XS GW3000-XS PV String Input Data Overvoltage Category Definition Max. DC Input Power (W) 2600 3250 3900 Max. DC Input Voltage (V) Category I: applies to equipment connected to a circuit where measures have been taken to MPPT Range (V) 50~450 50~450...

This manual is also suitable for:

Gw700-xsGw1000-xsGw1500-xsGw2000-xsGw2500-xsGw3000-xs

Table of Contents