Download Print this page
Goodwe GW1500-NS User Manual

Goodwe GW1500-NS User Manual

Ns/dns series
Hide thumbs Also See for GW1500-NS:

Advertisement

Official Website
Company Wechat
GoodWe(China)
No.189 Kunlunshan Rd.,SND,
Suzhou,215163,China
T: 400 998 1212
service.chn@goodwe.com.cn
www.goodwe.com.cn
GoodWe(Netherlands)
service.nl@goodwe.com.cn
www.goodwe.com.cn
Note: The information above is subject to change without prior notice,details refer to www.goodwe.com.cn.
GoodWe(Australia)
service.au@goodwe.com.cn
www.goodwe.com.cn
GoodWe(UK)
enquiries@goodwe.co.uk
www.goodwe.co.uk
NS/DNS SERIES USER MANUAL
SOLAR INVERTER

Advertisement

loading

Summary of Contents for Goodwe GW1500-NS

  • Page 1 NS/DNS SERIES USER MANUAL GoodWe(Australia) GoodWe(China) No.189 Kunlunshan Rd.,SND, service.au@goodwe.com.cn Suzhou,215163,China www.goodwe.com.cn T: 400 998 1212 service.chn@goodwe.com.cn www.goodwe.com.cn SOLAR INVERTER GoodWe(Netherlands) GoodWe(UK) enquiries@goodwe.co.uk service.nl@goodwe.com.cn www.goodwe.co.uk www.goodwe.com.cn Note: The information above is subject to change without prior notice,details refer to www.goodwe.com.cn.
  • Page 2: Table Of Contents

    1 Symbols ......................01 2 Safety ......................01 3 Installation 3.1 Mounting Instructions ......02 3.2 Inverter Overview and Package ....02 3.3 Inverter Installation ......03 ....... 05 3.4 Electrical Connection 4 System Operation 4.1 Indicator Lights ........13 ..
  • Page 3: Mounting Instructions

    Please install inverter in the place where is not exposed to direct sunlight, rain and snow. 2 Safety The NS/DNS series inverter of Jiangsu GoodWe Power Supply Technology Co, Ltd. (hereinafter referred to as GoodWe) strictly conforms to related safety rules in design and test. Safety regulations relevant to the location shall be followed during 3.2 Inverter Overview and Package...
  • Page 4: Inverter Installation

    1. PV input terminals 2. DC Switch (Optional) 3. RS-485 port or USB port 4. Wi-Fi antenna port (Optional) 5. CT and DRED function (Optional) 6. AC output terminal 7. LCD display 8. Indicator lights 9. Button 3.2.2 Package To allow dissipation of heat, and for convenience of dismantling, clearances around the inverter must be at least: The installation position shall not prevent access to the disconnection means.
  • Page 5: Electrical Connection

    Installation instruction of VACONN series please refer to Figure 3.4.1-2. fasten screw cap clockwise Material (Annealed copper wire) fasten screw cap clockwise Fastening three screws to ensure each screw head is not exceeding the surface Installation instruction of WIELAND series please refer to Figure 3.4.1-3. fasten screw cap clockwise 4mm Copper Conductor Material (Annealed copper wire)
  • Page 6: Dc Side Connection

    7mm around Bare Wire Length Recommended circuit breaker specifications Inverter model (Suggest using 4mm PV1-F wire) GW1000-NS/GW1500-NS/GW2000-NS/GW2500-NS Installation instruction of SUNCLIX please refer to Figure 3.4.3-3. GW3000-NS/GW3000D-NS/GW3600-NS/GW3600D-NS GW4200-NS/GW4200D-NS/GW5000-NS/GW5000D-NS Positive connector Note: Multiple inverters are not allowed to share a circuit breaker.
  • Page 7: Rs485 Communication

    3.4.4 Earth Terminal Connection 3.4.6 RS485 Communication The inverter is added earth terminal according to the requirement of EN 50178. It is must that installation person should connect the This function is only applied to inverters with RS485. terminal to earthing wire. The RS485 interface is used to connect EzLogger Pro and the maximum total length of all connecting cables should not exceed 800m.
  • Page 8 The Wi-Fi communication function is only applied to WiFi BOX, the detailed configuration instruction can be referred to Wi-Fi Configuration in the accessory box. After configuration, please browse http://www.goodwe-power.com to create PV station. 3.4.8 Power Limiting Device & DRED Installation Connection method of Power Limiting device CT please refer to Figure 3.4.8-1.
  • Page 9: Indicator Lights

    First Level Menu Second Level Menu 4 System Operation Long press 2S Normal 50Hz GridDefault Pac=2595.5W Short press 4.1 Indicator Lights Long press 2S E-Today= 15.2KWh Lock Pac=2595.5W Short press E-Total=533.17KWh Pac=2595.5W Short press Vpv=325.5/325.5V Pac=2595.5W Short press Long press 2S Ipv= 4.1/ 4.1A No Error Pac=2595.5W...
  • Page 11: Special Adjustable Setpoints

    It is adjustable through special software ,if you want to use it ,plaese contact with after sales. The methods document of using the software can download from goodwe website or contact with after sales. Note: When sunlight is insufficient, the PV Inverter may continuously start up and shut down automatically due to insufficient power generated by the PV panels, which would not lead to inverter damage.
  • Page 12 Technical Data Technical Data High Frequency Isolation Nominal Output Power (W) VDE0126-1-1,AS4777.2,EN50438(PL),G83,ERDF-NOI-RES_13E,IEC61727,IEC62116 Max. Output Apparent Power (VA) Nominal Output Voltage (V) 220~230 220~230 220~230 220~230 220~230 Nominal Output Frequency(Hz) EN 61000-6-1,EN 61000-6-2,EN 61000-6-3,EN 61000-6-4 50/60 50/60 50/60 50/60 50/60 12.5 13.5 Max.
  • Page 13 The inverter has field adjustable function,such as trip points,trip times, reconnect times,active and invalid of QU curve,PU curve. It is adjustable through special software ,if you want to use it ,plaese contact with after sales. The methods document of using the software can download from goodwe website or contact with after sales.