Average refers to the average value of harmful gases measured in one week. Maximum
refers to the upper limit of harmful gases measured in one week, and the maximum
value cannot last for more than 30 minutes every day.
2.2.6
Grounding Requirements
This product adopts the floating ground system. Do not connect it with the ground.
During installation, do not connect the metal cover with the ground.
2.2.7
Anti-interference Requirements
Take interference prevention measures for the power supply system.
Keep the AP away from the grounding equipment or lightning and grounding
equipment of the power device as much as possible.
Keep the AP far away from high-frequency current devices such as high-power radio
transmitting station and radar launcher.
Take electromagnetic shielding measures when necessary.
2.2.8
Lightning Protection Requirements
The AP can guard against lightning strikes. As an electric device, it may still be damaged
by too strong lightning strikes. Take the following lightning protection measures:
Ensure that the ground cable of the uplink optical host is in good contact with the
ground.
Ensure that the neutral point of the AC power socket is in good contact with the
ground.
It is recommended that a power lightning arrester be installed in front of the power
input end to enhance the lightning prevention for the power supply.
)