Manual Operation

IMPORTANT:
Fan rotating direction can be manually changed
when the engine is running. Each time the ON side
of fan reverse rotation switch (1) is pressed, the
fan's rotating direction switches alternatively. While
switching the fan rotating direction, fan reverse
rotation indicator (2) flashes. When the fan rotates
in reverse direction, indicator (2) stays ON. When
fan reverse rotation switch (1) is pressed while fan
reverse rotation indicator (2) turns ON, indicator
(2) starts flashing. When the fan rotates in normal
direction, fan reverse rotation indicator (2) goes OFF.
Do not press fan reverse rotation switch (1) while
indicator (2) is flashing.
Always operate the switch while parked with the
parking brake. When the parking brake is released,
the fan reverse condition is automatically canceled
after 1 minute. In case abnormal situation occurs
such as engine coolant overheating, reverse rotation
may forcibly be stopped, or fan reverse rotation
switch may be disabled.
1. Close the side cover and the rear grille before operating
the switch.
2. Start the engine. Be sure to confirm that the parking
brake is applied. Press ON side of fan reverse rotation
switch (1) once. Fan reverse rotation indicator (2) should
start flashing. Approximately 1 minute later, the fan
rotates in reverse direction, and fan reverse rotation
indicator (2) stays ON.
3. After operation, press fan reverse rotation switch (1)
again to return the fan rotation to the normal direction.
OPERATOR'S STATION
1-69
ON
OFF (Neutral)
AUTO
2
1
MNEC-01-019