Aerotech Ensemble CL Hardware Manual page 93

Table of Contents

Advertisement

Maintenance
Table 5-2:
Control Board Jumper Configuration 
Jumper
Setting
(1)
JP2
1-2
2-3
(1)
JP3
1-2
2-3
(1)
JP4
1-2
2-3
(1) Default
Table 5-3:
Control Board Fuse Information 
Fuse
Description
F1
TB102; AC Input Motor Power
Fuse
F2
TB102; AC Input Motor Power
Fuse
F6
TB103-1; AC Input Control
Power Fuse
Table 5-4:
LED Description
LED
ENB/FLT
MARKER
PWR*
POS
* If the power light flashes continuously and the unit does not operate, there is too much current draw from the 5V power supply or
the control supply voltage level is low.
www.aerotech.com
Description
Watchdog enabled
Watchdog disabled
24 V operation (High Speed Input 5)
5 V operation (High Speed Input 5)
24 V operation (High Speed Input 4)
5 V operation(High Speed Input 4)
Size
5 A S.B.
5 A S.B.
2 A S.B.
Description
Turns green to indicate that the axis is enabled. Turns red to indicate a fault con-
dition. The ENB/FLT LED will flash between RED and GREEN if the drive is
enabled and in a fault condition.
Turns green to indicate that the marker input is high.
Turns green when power is applied.
Turns green to indicate that the axis is in position.
Chapter 5
Aerotech P/N
Manufacturer's P/N
EIF1026
LittelFuse 3721500041
EIF1026
LittelFuse 3721500041
EIF1029
LittelFuse 3721200041
Ensemble CL
79