Chapter 5: Maintenance - Aerotech Ensemble CL Hardware Manual

Table of Contents

Advertisement

Maintenance

Chapter 5: Maintenance

This section covers the internal boards, important board components, and how to clean the drive.
Troubleshooting is covered in-depth in the Ensemble Help file.
D A N G E R : Always disconnect the Mains power connection before opening the Ensemble CL
chassis.
D A N G E R : Before performing any tests, be aware of lethal voltages inside the controller and
at the input and output power connections. A qualified service technician or electrician should
perform these tests.
Table 5-1:
LED Description
LED
ENB/FLT
MARKER
PWR*
POS
* If the power light flashes continuously and the unit does not operate, there is too much current draw from the 5V power supply or
the control supply voltage level is low.
www.aerotech.com
Description
Turns green to indicate that the axis is enabled. Turns red to indicate a fault con-
dition. The ENB/FLT LED will flash between RED and GREEN if the drive is
enabled and in a fault condition.
Turns green to indicate that the marker input is high.
Turns green when power is applied.
Turns green to indicate that the axis is in position.
Chapter 5
Ensemble CL
77

Advertisement

Table of Contents
loading