End Of Travel Limit Input Interface (J104); Table 2-16: End Of Travel Limit Input Interface Pin Assignment (J104) - Aerotech Ensemble CL Hardware Manual

Table of Contents

Advertisement

Ensemble CL

2.3.5. End Of Travel Limit Input Interface (J104)

End of Travel (EOT) limits are required to define the end of the physical travel on linear axes. Positive or
clockwise motion is stopped by the clockwise (CW) end of travel limit input. Negative or counterclockwise
motion is stopped by the counterclockwise (CCW) end of travel limit input. The Home Limit switch can be
parameter configured for use during the home cycle, however, the CW or CCW EOT limit is typically used
instead. All of the end-of-travel limit inputs accept 5-24 VDC level signals. Limit directions are relative to the
encoder polarity in the status display (refer to
The active state of the EOT limits is software selectable (by the EndOfTravelLimitSetup
Opto-isolated user inputs 0-3 can also be used as the end-of-travel limit inputs, see
MOTOR FEEDBACK
Table 2-16:
End of Travel Limit Input Interface Pin Assignment (J104)
Pin#
Description
12
Clockwise End of Travel Limit
16
+5V Power for Limit Switches (500 mA max)
20
Signal Common for Limit Switches
22
Home Switch Input
24
Counterclockwise End of Travel Limit
1
EndofTravelLimitSetup has replaced LimitLevelMask in software version 3.00.000.
38
Figure
13
+5V
25
Limit Com
J104
CW
CCW
Home
14
1
Figure 2-25:
End of Travel Limit Input Connections
Chapter 2
Installation and Configuration
2-27).
16
Normally closed shown (typical).
20
12
24
22
1
parameter).
Section 2.5.4.
May be a
separate switch.
In/Out/Bi
Input
Output
N/A
Input
Input
www.aerotech.com