Aerotech Ensemble CL Hardware Manual page 28

Table of Contents

Advertisement

Ensemble CL
1ST CL
28 VAC 10A MAX
0 VAC-CT
28 VAC 10A MAX
50/60Hz
A
B
C
CONTROL
SUPPLY
TB103
Use to power User-Supplied
HAZARDOUS VOLTAGES PRESENT
1. See the TM3 or TM5 manual for input voltage congfiguration.
2. The TM3 must be configured for 56CT VAC output.
3. Transformer Wiring: 0.5 mm
4. Control Supply output voltage (115 VAC in this example) is always the same as the AC Input Voltage to the unit.
Figure 2-5:
14
TM3/TM5 TRANSFORMER MODULE
AC1
AC2
28V
CT
28V
AC1
AC2
2nd CL
ESTOP circuitry
CONNECT ALL WIRING BEFORE
POWERING TRANSFORMER
2
(#20 AWG) 300 V wire.
Control and Motor Power Wiring using a TM3 or TM5 Transformer
Chapter 2
Installation and Configuration
28~
28~
28~
28~
0~
0~
L
L
115~
115~
N
N
28~
28~
28~
28~
0~
0~
L
L
115~
115~
N
N
24VDC 1A MAX
+
Transformer
Module
AEROTECH.
COM
DA N G E R !
H i g h Vo l t a ge
ON
|
O
OFF
FOLLOW ALL APPLICABLE WIRING
AND SAFETY CODES.
28V
CT
28V
AC1
AC2
3rd CL
28V
CT
28V
AC1
AC2
4th CL
www.aerotech.com

Advertisement

Table of Contents
loading

Table of Contents