Control Supply Connections (Tb103); Table 2-1: Control Supply Ac Input Wiring; Table 2-2: Control Supply Mating Connector - Aerotech Ensemble CL Hardware Manual

Table of Contents

Advertisement

Ensemble CL

2.1.1. Control Supply Connections (TB103)

N O T E : This product requires two power supply connections. The Motor Supply and Control Supply
must both be connected for proper operation.
The control power supply input allows the Ensemble CL to maintain communications if the motor power is
removed, such as in an Emergency Stop condition. The control power supply requires a minimum of 85 VAC
input to operate properly. The AC1 input is internally fused. The AC2 input is not internally fused but can be
connected to a voltage source other than Neutral if an external 2 A time-delay fuse is used.
Although the control power supply contains an internal filter, an additional external filter located as close as
possible to the Ensemble CL may be required for CE compliance (Aerotech recommends Schaffner
FN2080).
Line (L)
Neutral (N)
Ground
Table 2-1:
Control Supply AC Input Wiring
Pin
AC1
Line (L): 85-240 VAC Control Power Input
AC2
Neutral (0V) or 85-240 VAC Control Power Input with external fuse
Protective Ground (Required for Safety)
(1) AC1 and AC2 must be supplied from a branch protected source.
Table 2-2:
Control Supply Mating Connector
Type
3-Pin Terminal Block
10
Line Filter
Figure 2-1:
Control Supply Connections
Description
Aerotech P/N
Phoenix P/N
ECK01387
1803581
Chapter 2
Installation and Configuration
CONTROL
SUPPLY
TB103
AC1
AC2
50/60HZ
85-240V~
1A MAX
Recommended Wire
0.8 mm
0.8 mm
0.8 mm
Tightening
Torque (Nm)
Wire Size: mm
0.22 - 0.25
2.0 - 0.516 [14-30]
www.aerotech.com
Size
2
(#18 AWG)
2
(#18 AWG)
2
(#18 AWG)
2
[AWG]

Advertisement