Warning Message; Error Message - DEMAG DIC 002 Series Operating Instructions Manual

Table of Contents

Advertisement

9.3

Warning message

The key to be read out via the Warnings 269 parameter may consist of several messages. Key A0088 indicates
individual warning messages A0008 + A0080, for example.
For SAxxx and SFxxx messages, see  "Setup", Page 58.
Warning Status coding
AXXXX
I
Warning key
Code
Warning Status
A0000
-
No warning messages.
A0001
Ixt
Frequency inverter overloaded, (A0002 or A0004)
A0002
IxtSt
Short-term overload for 10 seconds with reference to the rated output of the frequency inverter
A0004
IxtLt
Overload for 60 seconds with reference to the rated output of the frequency inverter
Tc
The max. heat sink temperature T
A0008
Ti
Max. Interior temperature T
A0010
Lim
The controller listed in Controller Status 275 limits the setpoint value.
A0020
A0040
LK
The load spectrum function signals that 90% of the service life of the hoist unit has elapsed.
PTC
Warning after programmed Motor-PTC Operation Mode 570 at max. motor temperature T
A0080
Mains
Phase Supervision 576 signals a phase failure in the power supply.
A0100
PMS
The internal software motor circuit-breaker has been tripped according to the programmed Operation Mode 571 of the
A0200
Motor Protective Switch function
A0400
Flim
The Maximum frequency 419 has been exceeded. Frequency limitation is active
A0800
A1
The MFI1A input signal is lower than 1 V/2 mA depending on Operation Mode Error/Warning Behaviour 453
A2
Only with EM – UNI-01 extension module
A1000
The EM-S1INA input signal is lower than 1 V/2 mA depending on operation mode Error/Warning Behaviour 563
A2000
Sysbus
A slave on the system bus reports an error, warning only relevant with EM – UNI-01 option.
A4000
UDC
The link voltage has reached the type-dependent minimum value
A8000
Warn 2
Application Warning Status "DIC positioning operating instructions"  Tab. 1, Page 2
Tab. 82
9.4

Error message

The fault code saved in the Last Error 310 parameter following an error facilitates fault-finding and diagnosis.
The error message must be acknowledged using the keys on the keypad unit, (see  "Programming parameters
with the KP500 keypad unit", Page 53).
For SAxxx and SFxxx messages, see  "Setup", Page 58.
Error messages
Function
Code
F0000
F0102
Overload
F0103
F0200
Heat sink
F0201
F0300
Interior
F0301
F0400
F0401
Motor con‐
nection
F0403
F0405
F0500
F0503
F0504
Output cur‐
rent
F0505
F0506
F0507
74
of 80 °C minus the Warning Limit Heat Sink Temp. 407 has been reached
K
of 65 °C minus the Warning Limit Inside Temp. 408 has been reached
K
Meaning
No fault has occurred.
Frequency inverter overloaded (60 sec), check load behaviour.
Short-term overload (10 sec), check the motor and application parameters.
Heat sink temperature too high, check cooling and fan.
Temperature sensor defective or ambient temperature too low.
Interior temperature too high, check cooling and fan.
Interior temperature too low, check the switchgear cabinet heating.
Motor temperature too high or sensor defective, check motor thermal contact connection.
The motor circuit-breaker has tripped. Check drive.
Motor phase failure, check motor and wiring.
Brake release monitoring
Overload, check load conditions and ramps.
Short circuit or earth fault, check motor and wiring.
Overload, check load conditions and current limit controller.
Asymmetrical motor current, check motor and wiring.
Motor phase current too high, check motor and wiring.
Message from phase monitoring, check motor and wiring.